Compressor Components Overview - Bosch HP270-2 Technical Manual

Domestic hot water heat pump
Table of Contents

Advertisement

Between C – R > 0
Highly ≈ 5.84 Ω
Between C – S > 0
Highly ≈ 7.62 Ω
Between R – S > 12 Ω
(values @ 20ºC)
Check earth connection
C – chassis ≠ 0
S – chassis ≠ 0
R – chassis ≠ 0
Attention:
In
case
continuity the compressor
is defected
Thermal Protection
This function is ensured by
a
bimetallic
temperature
limiter
which
opens
contact
when
temperature
(T=160ºC
±10ºC) is reached during
operation.
Page 16 from 56
Checking Continuity and Resistance (Ω):
Electric test to compressor:
of
Testing of thermal protection limiter:
its
high
Open contact
temperature activation – T≥160ºC
Table 4 – Compressor components overview
6-720-821-364 SM HP270 – 250 - 200 2016/12 en
Close contact
normal operation – T<70ºC