Protection Modes; Anti-Freeze Protection - Bosch HP270-2 Technical Manual

Domestic hot water heat pump
Table of Contents

Advertisement

Boost Mode
Conditions

2.2) Protection Modes

Anti-Freeze Protection

The anti freeze protection is designed to protect both the module and the tank and is active in all conditions,
specially, when the appliance is set in Heat Pump, standby, OFF and Holyday (Hol) modes.
Note: In order to ensure the anti freeze protection activation, the mains plug must not be disconnected.
Module Protection
Start Up Condition:
T
< 4ºC
Bottom
Tank Protection
Start Up Condition:
T
< 5ºC
top
Only HP270-3 and HP200/250-1:
Integrated E-Heater in module
Pump + Electric
Heater ON
Page 10 from 56
ON if compressor is
ON:
Note: If Duct On
and T
starts 2 min before
and T
compressor and if
Duct Off starts 1 min
before compressor in
order to update air
temperature value
Table 3 – Operation Modes Conditions
Pict.6 – Heat Pump Diagram (Model HP270-2: -10ºC / +35ºC)
6-720-821-364 SM HP270 – 250 - 200 2016/12 en
ON if -10ºC <
OFF
T
< +35ºC
air
< 61ºC
dis
< 58ºC
top
ON if
ON
compressor is
ON
or
ON if E-heater
ON when
compressor is
OFF
Module Protection
Stop Condition:
Until T
> 6ºC + Water Pump
bottom
ON during 1 min
Tank Protection
Stop Condition:
E-Heater ON until T
top
(not in case of Full or Legionela activation)
Pump + Electric Heater ON
> 8ºC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hp270-3Hp200-1Hp250-1

Table of Contents