LOCAL POWER CONTROL
for AC Outlet number 6
receives a turn-on signal (5
to 12 volts) from a McIntosh
component and the LOCAL
POWER CONTROL OUT
sends a turn-on signal (same
voltage as the Power Control
Input) on to another McIntosh
component. The LED indi-
cates when the AC Outlet is
active. The LOCAL POWER
CONTROL switch selects
LOCAL, GLOBAL or always
ON activation
M
P
C
1
5
0
0
-
E
U
SWITCHED AC Outlet
controlled by LOCAL
POWER CONTROL
number 6 Switch Set-
ting and/or the received
Power Control Signal
SWITCHED AC Outlet controlled
by LOCAL POWER CONTROL
number 5 Switch Setting and/or
the received Power Control Signal
16
LOCAL POWER CONTROL
LOCAL POWER CONTROL
for AC Outlet number 5
for AC Outlet number 4
receives a turn-on signal (5
receives a turn-on signal (5
to 12 volts) from a McIntosh
to 12 volts) from a McIntosh
component and the LOCAL
component and the LOCAL
POWER CONTROL OUT
POWER CONTROL OUT
sends a turn-on signal (same
sends a turn-on signal (same
voltage as the Power Control
voltage as the Power Control
Input) onto another McIntosh
Input) onto another McIntosh
component. The LED indi-
component. The LED indi-
cates when the AC Outlet is
cates when the AC Outlet is
active. The LOCAL POWER
active. The LOCAL POWER
CONTROL switch selects
CONTROL switch selects
LOCAL, GLOBAL or always
LOCAL, GLOBAL or always
ON activation
ON activation
SWITCHED AC Outlet controlled
by LOCAL POWER CONTROL
number 4 Switch Setting and/or the
received Power Control Signal
LOCAL POWER CONTROL
for AC Outlet number 3
receives a turn-on signal (5
to 12 volts) from a McIntosh
component and the LOCAL
POWER CONTROL OUT
sends a turn-on signal (same
voltage as the Power Control
Input) onto another McIntosh
component. The LED indi-
cates when the AC Outlet is
active. The LOCAL POWER
CONTROL switch selects
LOCAL, GLOBAL or always
ON activation
SWITCHED AC Outlet controlled
by LOCAL POWER CONTROL
number 3 Switch Setting and/or
the received Power Control Signal

Rear Panel Connections

GLOBAL POWER CONTROL
IN receives a turn-on-signal (5
to 12 volts) for the Local Power
Control selection of Global and
the GLOBAL POWER CON-
TROL OUT sends a delayed
turn-on signal (12 volts) to other
McIntosh Component(s)
The LEDs indicate the
MPC1500 Power Control-
ler is connected to a live
AC Outlet and the UN-
SWITCHED AC OUTLETs
number 1 and 2 are active.
CIRCUIT BREAKER
press to reset if the
MPC1500 Power Con-
troller will not power up
Connect the MPC1500
power cord to a live AC
outlet. Refer to informa-
tion on the back panel of
your MPC1500 to deter-
mine the correct voltage
for your unit
Unswitched AC outlets
number 1 and 2 are ac-
tive when the MPC1500
is connected to a live
AC Outlet