Ingersoll-Rand S9V2B060U3PSBA Installer's Manual

Ingersoll-Rand S9V2B060U3PSBA Installer's Manual

Upflow/horizontal and downflow gas-fired, direct/non-direct vent, 2–stage condensing variable speed furnaces
Hide thumbs Also See for S9V2B060U3PSBA:

Advertisement

Installer's Guide
Upflow/Horizontal and Downflow
Gas-Fired, Direct/Non-Direct Vent, 2–Stage
Condensing Variable Speed Furnaces
U U p p f f l l o o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
S9V2B040U3PSBA
S9V2B060U3PSBA
S9V2B060U4PSBA
S9V2B080U3PSBA
S9V2B080U4PSBA
S9V2C080U5PSBA
S9V2C100U4PSBA
S9V2C100U5PSBA
S9V2D120U5PSBA
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and
air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the
literature and on the tags, stickers, and labels that are attached to the equipment.
February 2017
D D o o w w n n f f l l o o w w O O n n l l y y
S9V2B040D3PSBA
S9V2B060D3PSBA
S9V2B080D3PSBA
S9V2B080D4PSBA
S9V2C100D4PSBA
S9V2C100D5PSBA
S9V2D120D5PSBA
D345855P01
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
1 1 8 8 - - C C E E 0 0 1 1 D D 1 1 - - 1 1 F F - - E E N N
N N o o t t e e : : Graphics in this document are for representation
only. Actual model may differ in appearance.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S9V2B060U3PSBA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ingersoll-Rand S9V2B060U3PSBA

  • Page 1 H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r S9V2B040D3PSBA H H o o r r i i z z o o n n t t a a l l L L e e f f t t S9V2B060D3PSBA S9V2B040U3PSBA S9V2B080D3PSBA S9V2B060U3PSBA S9V2B080D4PSBA S9V2B060U4PSBA S9V2C100D4PSBA S9V2B080U3PSBA S9V2C100D5PSBA...
  • Page 2 SAFETY SECTION— FURNACES W W A A R R N N I I N N G G I I n n g g e e r r s s o o l l l l R R a a n n d d h h a a s s a a p p o o l l i i c c y y o o f f c c o o n n t t i i n n u u o o u u s s p p r r o o d d u u c c t t a a n n d d p p r r o o d d u u c c t t d d a a t t a a i i m m p p r r o o v v e e m m e e n n t t a a n n d d i i t t r r e e s s e e r r v v e e s s t t h h e e E E X X P P L L O O S S I I O O N N H H A A Z Z A A R R D D ! ! r r i i g g h h t t t t o o c c h h a a n n g g e e d d e e s s i i g g n n a a n n d d s s p p e e c c i i f f i i c c a a t t i i o o n n s s w w i i t t h h o o u u t t...
  • Page 3 S S A A F F E E T T Y Y S S E E C C T T I I O O N N — — F F U U R R N N A A C C E E S S W W A A R R N N I I N N G G W W A A R R N N I I N N G G F F I I R R E E H H A A Z Z A A R R D D ! !
  • Page 4 S S A A F F E E T T Y Y S S E E C C T T I I O O N N — — F F U U R R N N A A C C E E S S W W A A R R N N I I N N G G W W A A R R N N I I N N G G E E X X P P L L O O S S I I O O N N H H A A Z Z A A R R D D ! !
  • Page 5 S S A A F F E E T T Y Y S S E E C C T T I I O O N N — — F F U U R R N N A A C C E E S S W W A A R R N N I I N N G G C C A A U U T T I I O O N N O O V V E E R R H H E E A A T T I I N N G G A A N N D D E E X X P P L L O O S S I I O O N N...
  • Page 6 S S A A F F E E T T Y Y S S E E C C T T I I O O N N — — F F U U R R N N A A C C E E S S C C A A U U T T I I O O N N C C A A U U T T I I O O N N D D O O N N O O T T U U S S E E A A S S C C O O N N S S T T R R U U C C T T I I O O N N...
  • Page 7 S S A A F F E E T T Y Y S S E E C C T T I I O O N N — — F F U U R R N N A A C C E E S S W W A A R R N N I I N N G G C C A A U U T T I I O O N N C C A A R R B B O O N N M M O O N N O O X X I I D D E E P P O O I I S S O O N N I I N N G G...
  • Page 8: Table Of Contents

    Table of Contents Accessories....... . . 9 General Start-up and Adjustment..65 Document Pack Contents .
  • Page 9: Accessories

    Accessories Table 1. Accessories Model Number Description Use with BAYHANG Horizontal Hanging Kit All Upflow Furnaces BAYVENT200B Sidewall Vent Termination Kit All Furnaces BAYVENTCN200B Sidewall Vent Termination Kit (Canada — All Furnaces CPVC) BAYAIR30AVENTA Concentric Vent Kit All Furnaces BAYAIR30CNVENT Concentric Vent Kit (Canada —...
  • Page 10: Furnace Installation Guidelines

    Furnace Installation Guidelines The following sections give general guidelines for the c. The Furnace return air duct must be complete installation of the gas furnaces. and sealed to the Furnace. d. The Furnace input rate and temperature rise Safety Practices and Precautions must be verified to be within the nameplate marking.
  • Page 11: Locations And Clearances

    F F u u r r n n a a c c e e I I n n s s t t a a l l l l a a t t i i o o n n G G u u i i d d e e l l i i n n e e s s These Furnaces have been classified as CATEGORY IV 1 In.
  • Page 12: Outline Drawings

    Outline Drawings 18-CE01D1-1F-EN...
  • Page 13 O O u u t t l l i i n n e e D D r r a a w w i i n n g g s s 18-CE01D1-1F-EN...
  • Page 14 O O u u t t l l i i n n e e D D r r a a w w i i n n g g s s 18-CE01D1-1F-EN...
  • Page 15 O O u u t t l l i i n n e e D D r r a a w w i i n n g g s s 18-CE01D1-1F-EN...
  • Page 16 O O u u t t l l i i n n e e D D r r a a w w i i n n g g s s 18-CE01D1-1F-EN...
  • Page 17 O O u u t t l l i i n n e e D D r r a a w w i i n n g g s s 18-CE01D1-1F-EN...
  • Page 18: Furnace General Installation

    Furnace General Installation S-Series Furnace Panel Removal The following sections give general instructions for the installation of the gas furnaces. Note: Use a 5/16” Allen wrench to remove the front panel. Fits 5/16” Allen wrench 18-CE01D1-1F-EN...
  • Page 19: Gas Piping

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Gas Piping Important: When converting the gas piping from the factory default, the plug must be removed from the new gas piping...
  • Page 20 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Important: When converting the gas piping from the factory default, the plug must be removed from the new gas piping location and swapped with the grommet from the default...
  • Page 21 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n The upflow/horizontal furnace is shipped standard for left side installation of gas piping.
  • Page 22: Combustion And Input Check

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Combustion and Input Check Make sure all gas appliances are off except the furnace.
  • Page 23: Gas Valve Adjustment

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Gas Valve Adjustment Changes can be made by adjusting the manifold pressure, or changing orifices (orifice change may not always be required).
  • Page 24: High Altitude Derate

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n High Altitude Derate Input ratings (BTUH) of these Furnaces are based on sea level operation and should not be changed at elevations up to 2,000 ft.
  • Page 25: General Venting

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n General Venting FURNACE EXHAUST MUST BE VENTED TO THE OUTDOORS.
  • Page 26: Special Case Venting

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Special Case Venting Special instructions for direct vent furnace air intake.
  • Page 27 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Option 2 —...
  • Page 28: Vent Terminations

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Vent Terminations For DIRECT VENT APPLICATION: The Furnaces must be vented to Vent terminations...
  • Page 29 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n ATTACHING VENT PIPING Important: Products installed in Canada must use vent systems that are certified to the Standard for Type BH Gas Venting...
  • Page 30 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n APPROVED VENT PIPE MATERIALS PVC VENT FITTING MATERIAL These fittings are available from your Gas Furnace Distributors.
  • Page 31: Maximum Vent Length Table

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Maximum Vent Length Table Maximum Total Equivalent Length In Feet Maximum Vent Length Table...
  • Page 32: Horizontal Venting

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Horizontal Venting 3”...
  • Page 33 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n COMBUSTIBLE MATERIAL WALL A minimum clearance of 1"...
  • Page 34: Horizontal Venting Through Wall

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Table 2.
  • Page 35: With Concentric Vent Kit

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Horizontal Venting Through Wall with Concentric Vent Kit These Furnaces may be installed as direct vent (as shipped) or BAYVENT200B / BAYVENTCN200B...
  • Page 36 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Important: The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for installation of through –...
  • Page 37 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Non-Direct Vent Termination Clearances Canadian Installations US Installations...
  • Page 38 F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Direct Vent Termination Clearances Canadian Installations US Installations...
  • Page 39: Venting Through The Roof

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n Venting Through The Roof Support Horizontal pipe every 3’0”...
  • Page 40: Options

    F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n When penetrating roof with PVC vent pipe, a flexible flashing may be used for a weather tight seal.

Table of Contents

Save PDF