AHSE Uninstall / install appliance switch
050 Maintenance and inspection
Service group does not contain any maintenance and in-
spection points.
060 Error diagnosis
Findings
Pump does not run or suddenly comes
to a standstill during operations
070 Peculiarities/ others
The service group does not contain any peculiarities.
110 Replacement times
Basic work
Description
AHNK
Uninstalling / installing mains cable
AHKS
Uninstalling / installing capacitor
AHSE
Uninstall / install appliance switch
ABGH Uninstall / install appliance hood
1 Guidance
2 Lever appliance switch
3 Plug connections
4 Power switch
5 Covering lid
Unclip casing cover.
Unhook lever of appliance switch.
Remove appliance switch.
Disconnect the connectors.
Note
Observe the plug arrangement during installation.
Pay attention to the correct fitting position during reinstal-
lation.
Possible cause
Power supply interrupted
Power switch
Power switch
S1
Correction
Check fuses and electrical connections
Check appliance switch.
Check the electrical connections.
Work value
English 5.906-591.0 Rev. 00 (01/14)