Configuring A Bfd Template; Enabling Snmp Notifications - HP MSR Series Configuration Manual

High availability
Hide thumbs Also See for MSR Series:
Table of Contents

Advertisement

Step
6.
Set the minimum interval for
receiving multihop BFD control
packets.
7.
Set the minimum interval for
transmitting multihop BFD
control packets.

Configuring a BFD template

Perform this task to specify BFD parameters in a template for sessions without next hops. You can
configure BFD parameters for LSPs and PWs through a BFD template.
To configure a BFD template:
Step
1.
Enter system view.
2.
Create a BFD template and
enter BFD template view.
3.
Configure the authentication
mode for BFD control packets.
4.
Set the detection time
multiplier.
5.
Set the minimum interval for
receiving BFD control packets.
6.
Set the minimum interval for
transmitting BFD control
packets.

Enabling SNMP notifications

Perform this task to enable SNMP notifications for BFD to report important events. Notifications are
delivered to the SNMP module, which outputs the notifications according to the configured output rules.
For more information about SNMP notifications, see Network Management and Monitoring
Configuration Guide.
To enable BFD to send SNMP notifications:
Step
1.
Enter system view.
Enable BFD to send
2.
SNMP notifications.
Command
bfd multi-hop min-receive-interval
value
bfd multi-hop min-transmit-interval
value
Command
system-view
bfd template template-name
bfd authentication-mode { m-md5 |
m-sha1 | md5 | sha1 | simple }
key-id { cipher cipher-string | plain
plain-string }
bfd detect-multiplier value
bfd min-receive-interval value
bfd min-transmit-interval value
Command
system-view
snmp-agent trap enable bfd
69
Remarks
The default setting is 1000
milliseconds.
The default setting is 1000
milliseconds.
Remarks
N/A
By default, no BFD template is
created.
By default, no authentication is
performed.
BFD version 0 does not support this
command. Configuring this
command for BFD version 0 does
not take effect.
The default setting is 5.
The default setting is 1000
milliseconds.
The default setting is 1000
milliseconds.
Remarks
N/A
By default, BFD is enabled to send
SNMP notifications.

Advertisement

Table of Contents
loading

Table of Contents