Chapter 1. General Description; Specifications - Sharp FO-145 Service Manual

Hide thumbs Also See for FO-145:
Table of Contents

Advertisement

FO-145A
—.
—- —--
CHAPTER
1. GENERAL DESCRIPTION
[1]
SPECIFICATIONS
Applicable
telephone line:
Compatibility:
Configuration:
Compression scheme:
Scanning method:
Resolution:
Recording system:
Display:
Reception modes:
Modem speed:
Transmission time*:
Effective recording width:
Input document size:
Public switched telephone network
ITU-T (CCl~) G3 mode
Half-duplex, desktop transceiver
Modified Huffman and Sharp special
mode
Flat-bed, solid-state CCD
Horizontal:
8 lines/mm
Vertical:
Standard —
3.85 lines/mm
Fine/Haiftone — 7.7 lines/mm
Thermal recording
7 x 5 dots, 1 line by 16-digit display
Auto/Manual/Answering machine
9600 bps with automatic fallback to
7200, 4800, or 2400 bps
Approx. 15 seconds
(Sharp special mode)
210 mm, max.
Automatic feeding:
Width — 148 to 216 mm
Length — 128 to 297 mm
Manual feeding:
Width — 148 to 216 mm
Length — 128 to 1000 mm
Effective scanning width:
210 mm, max.
Automatic document feeder: 18 sheets max.
Halftone (gray scale):
32 levels
Contrast control:
Automatic/Darkselectable
Copy function:
Standard
Telephone function:
Standard
(cannotbe used if power fails)
Power requirements:
230–240 V AC, 50 tiz
Operating temperature:
5 to
35°C
Power consumption:
Stand-by: 7 W
Transmission: 15 W
Reception: 22 W
copy: 25 W
maximum: 120 W
Dimensions:
Width: 353 mm
Depth: 259 mm
Height: 122 mm
Weight:
Approx. 3.7 kg
x Based on ITU-T (CCllT) Test Chart #l at standard resolution in
Sharp special mode, excluding time for protocol signals (i.e.,
ITU-T phase C time only).
As a part of our policy of continuous improvement, SHARP resewes the right to make design and specification changes for procduct
improvement without prior notice. The performance specifications figures indicated are nominal values of production units. There may be some
deviation from these values in individual units.
1–1

Advertisement