Warranty And Contact Information - Blue Sea Systems 7531 User Manual

Table of Contents

Advertisement

Warranty and Contact Information

Register your P12 Battery Charger at bluesea.com/warranty
Blue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for any of its products found
to be defective in materials or manufacture. P12 Battery Chargers and P12 Remote Displays are warranted for a period of five years from the date of first
purchase. No compensation will be allowed for products not returned to Blue Sea Systems for analysis, nor will compensation be made for labor required
to replace any defective product. Please contact Customer Service for an RMA number prior to shipping any product back to Blue Sea Systems. Blue Sea
Systems cannot accept liability for damage due to the use of the P12 Battery Charger.
"Date of first purchase" means:
1. The date on which the product was purchased by the first retail customer
2. The date on which the first retail customer purchases a vessel on which the product was installed
Blue Sea Systems will (at its sole discretion) repair or replace any product which is:
1. Proven to be defective in materials or workmanship
2. Returned to Blue Sea Systems (or its agent) during the warranty period in accordance with this warranty
The replacement battery charger may be new or refurbished in as-new condition. Such repair or replacement will be the sole remedy by Blue Sea Systems
under this warranty. Any repaired or replacement product will be warranted in accordance with this warranty for the unexpired balance of the warranty period
on the original product.
Blue Sea Systems Technical Support
Monday through Friday
8:00am - 5:00pm (PST)
1-800-222-7617
techsupport@bluesea.com
Related Products
P12 Battery Charger LED Remote 7520
360 Panel - P12 Battery Charger LED Remote 1521
SI Series Automatic Charging Relay 7610
ML Series Automatic Charging Relay 7622
ML Series Remote Battery Switch 7700
Class-T Fuse Block 5502
Safety Fuse Block (MIDI®/AMI®) 7720
7520
1521
7610
7622
24
Specifications are subject to change. See bluesea.com/P12 for current information.
7700
5502
7720
P12 Charge Management System
Twin Engine
3 Battery Bank
360 Panel System
5
1
6
2
7
3
8
4
9
RBS
Alternator
Starter
11
12
Engine 1
Class-T
Fuse Block
15
House
16
PowerBar
(System Ground)
System Functions:
1
AC Amperage, Voltage, and Frequency measurement with alarms
2
AC ELCI Ground Fault Protection
3
AC Source Selection
4
AC Branch Circuit Protection and Switching
5
DC Battery Charger Remote Monitoring and Control
6
DC Amperage and Voltage measurement with alarms
7
DC Branch Circuit Protection and Switching
8
DC Remote Battery Isolation Switching
9
DC Remote Automatic Charging Relay (ACR) Switching
10
3 Bank Battery Charging
11
House Battery Isolation
12
Engine Battery Isolation
13
Charge Distribution Engine 1 – Engine 2 – House
14
Charge Coordination – ACR's Disabled if Battery Charger Active
15
DC Main Circuit Protection
16
System Ground
P12 Battery Charger
10
14
RBS
ACRs
RBS
Alternator
Starter
13
13
12
Engine 2
15
15
AMI®/MIDI® Fuse Block
AMI®/MIDI® Fuse Block
LEGEND
AC Line
Start 1
Start 2
DC Positive
System Ground
Control
Specifications are subject to change. See bluesea.com/P12 for current information.