Summary of Contents for Blue Sea Systems Battery LINK 7606
Page 1
BatteryLink ® Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion of Blue Sea Systems. To view the most current revision of this publication visit...
IMPORTANT SAFETY INSTRUCTIONS 1. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for the BatteryLink® Charger model 7606. 2. WARNING RISK OF EXPLOSIVE GASES. Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal battery operation. For this reason it is of the utmost importance that each time before using your charger, you read and follow the instructions provided exactly.
Page 3
BATTERYLINK® CHARGER OVERVIEW Mounting holes (4) Clearance for #10 or M5 mounting hardware. Hex recesses accept #10 (3/8" socket size) nuts. NOTE: Mounting holes are not symmetrical, please see dimensioned drawing. Charging and ACR status LEDs DC Output Battery negative connection 1/4"-20 studs accept 1/4"...
Page 4
BatteryLink ® Charger Features The BatteryLink® Charger is a 120V AC/230V AC nominal input, 12V DC nominal output, 20A battery charger with integral battery combiner (ACR) providing a second battery connection, as well as standard ACR function when AC power is not present. •...
Page 5
Battery Temperature Compensation Battery temperature compensation is output voltage regulation based on battery temperature variances. Since batteries can see extreme temperature differences, it is important to regulate output voltage with temperature to maximize battery life. A battery in a cold environment should not be charged at the same voltage as a battery in a hot environment. The BatteryLink®...
Page 6
10. Appropriate heat shrink if pre-terminated wires were not acquired. 11. Remote switch for Manual Combine feature if desired. Blue Sea Systems PN 8292 (momentary SPST) or 8282 (non-momentary SPST) suggested. 12. 7-10A circuit breaker recommended for connection to AC supply panel.
/ single-throw (SPST) switch. Switch not included. Suggested switches are Blue Sea Systems PN 8292 (momentary) or 8282 (non-momentary). Connect the other contact of the switch to your battery positive terminal through a 2A fuse at the battery. Place this connection on top of all current carrying conductors.
Page 8
QUICK INSTALLATION DIAGRAM ACCESSORIES BatteryLink™ Charger 20A ENGINE 7606 AC INPUT FUSE* AC Connections Line: Brown Neutral: Blue Ground: Green/Yellow FUSE** FUSE* FUSE* DC SAFETY GROUND*** AUXILIARY START BATTERY BATTERY NEGATIVE BUS BAR GROUND Legend DC Negative Optional DC Positive See Wire Size and Fuse Rating Table, page 5.
DIMENSIONED DRAWINGS 7.67" 194.8mm 0" 0.0mm TYP. 2X 0" 0.0mm TYP. 2X 5.65" 143.5mm 4.29" 108.9mm 4.70" 119.5mm THIS VIEW SHOWN WITH COVER REMOVED .09" FOR OPTIMAL PERFORMANCE, MOUNT 2.4mm VERTICALLY AS SHOWN, IN A WELL VENTILATED AREA. RECOMMENDED MOUNTING CLEARANCE 175mm MINIMUM ON ALL SIDES.
Specifications Nominal Output Voltage 12V DC Total Output Current 20A DC Output Connections 2 positive, 1 negative Universal AC Input Voltage 100V-240V AC Input Frequency Range 50/60 Hz AC Input Current 4.0A @ 100V 1.8A @ 200V Typical Float Voltage (25°C) 13.5V DC Typical Absorption Voltage (25°C) 14.4V DC...
EC DECLARATION OF CONFORMITY For the following equipment: Product type: Battery Charger 20A Type designation: BatteryLink Charger: 7606, 7607 Manufacturer: Blue Sea Systems, Inc. Address: 4600 Ryzex Way Bellingham, WA 98226 USA Phone: 001.360.738.8230 Herewith it is confirmed to comply with the requirements set out in the council directive, 2006/95/EC for electrical equipment used within certain voltage limits, the EMC directive 2004/108/EC , and the Recre- ational Craft Directive 2013/53/EU.
Need help?
Do you have a question about the Battery LINK 7606 and is the answer not in the manual?