Blue Sea Systems P12 Series User Manual
Hide thumbs Also See for P12 Series:
Table of Contents

Advertisement

Available languages

Available languages

User Manual
Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for P12 Battery Chargers.
This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion
of Blue Sea Systems. To view the most current revision of this publication visit bluesea.com/P12.
B A TT E R Y C HAR GER
7531 and 7532
P12
Scan for
additional
product
information

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P12 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Blue Sea Systems P12 Series

  • Page 1 Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for P12 Battery Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion of Blue Sea Systems. To view the most current revision of this publication visit bluesea.com/P12.
  • Page 2: Table Of Contents

    Table of Contents 7531 AND 7532 BATTE RY C HAR GER S Important Safety Instructions 1–2 P12 Battery Charger Overview 3–4 Specifications Installation Tables • Table A: Minimum Recommended Wire Size • Table B: Recommended DC Circuit Protection • Table C: Typical AC Regional Wire Colors •...
  • Page 3: Important Safety Instructions

    Each time before using your charger read this manual and follow the instructions. Do not use any accessory devices that directly connect to the charger other than those manufactured by Blue Sea Systems and designed for use with the P12 Battery Charger. Do not operate the charger if it has been dropped or damaged.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS 7531 AND 7532 BATTE RY C HAR GER S e) NEVER smoke or allow a spark or flame in vicinity of battery or engine. f) Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
  • Page 5: P12 Battery Charger Overview

    Absorption charging stage. This ensures batteries near their full charge do not continue to receive high constant voltages necessary in the Absorption stage. This is optimal treatment for long battery life. Charge Coordination integrates with the Blue Sea Systems family of Automatic Charging Relays (ACR) to force separation of the battery banks while the P12 is operational, to allow the batteries to individually exit the absorption stage.
  • Page 6 P12 Battery Charger Over view 7531 AND 7532 BATTE RY C HAR GER S Mounting holes Clearance for: M6, 1/4", or #12 mounting hardware NOTE: Mounting holes screw centers are not symmetrical. Please see dimension drawing on page 6 Fan vent Graphic LCD Display Screen selection buttons...
  • Page 7: Specifications

    Specifications 7531 AND 7532 BATTE R Y C HAR GE R S 7531 7532 Total Output Current (continuous) Input AC Current 4.5A @ 115V AC / 2.25A @ 230V AC 7.5A @ 115V AC / 3.75A @ 230V AC Nominal Output Voltage 12V DC 12V DC Output Connections...
  • Page 8 Product Dimensions 7531 AND 7532 BATTE RY C HAR GER S WARNING For drip proof performance, and to meet ABYC requirements, the P12 Battery Charger must be mounted vertically as shown below. 7.80" Clearance for This (198mm) #12, Ø1/4" M6 mounting hardware 12.94"...
  • Page 9: Included Components

    Included Components 7531 AND 7532 BATTE R Y C HAR GE R S P12 Battery Charger Hardware: DC Strain Relief Clamp Screws M3 x 25mm pan-head machine screws Recommended torque: 5–10 in-lb (0.6–1.1 Nm) AC Strain Relief Insulating Cover Screws M3 x 25mm pan-head machine screws (Use #1 Phillips screwdriver) Recommended torque: 5–10 in-lb (0.6–1.1 Nm)
  • Page 10: Supplies Needed

    Supplies Needed & Maintenance 7531 AND 7532 BATTE RY C HAR GER S 1. AC Wire (see Table D page 5) NOTE: Wire length must reach from the panel to the battery charger AC Connections with proper routing, support, drip loops, service loops, and termination. 2.
  • Page 11 Installation & Operating Instructions 7531 AND 7532 BATTE R Y C HAR GE R S WARNING Be sure the area around the charger and batteries is well ventilated while the batteries are being charged. This unit is must be located in a dry, well ventilated area, free from unsecured hardware.
  • Page 12: Installation Instructions

    Connect the Automatic Charging Relay(s) (ACR) wire to the ACR Connection port(s) NOTE: If you have a Blue Sea Systems ACR with Start Isolation it is possible to take advantage of the P12 Battery Charger’s ability to integrate with it. The P12 is designed to charge three electrically independent batteries or battery banks.
  • Page 13: Initial Charger Setup

    Initial Charger Setup 7531 AND 7532 BATTE R Y C HAR GE R S During Initial Charger Setup, or after resetting to factory defaults, the following screens require user input to provide functional battery charging. Using the left or right arrow button, scroll to the desired language.
  • Page 14: Advanced Charger Setup

    Advanced Charger Setup 7531 AND 7532 BATTE RY C HAR GER S Complete this setup to change language, limit fan noise, adjust backlight display and limit AC current draw. Press the Menu button. Press the left or right arrow buttons to scroll to the Fan Speed window Press the Select button.
  • Page 15: Reset To Manufacturer Defaults

    Advanced Charger Setup (continued) 7531 AND 7532 BATTE R Y C HAR GE R S 19. Once desired display settings are enabled press Back. 20. Press the left or right arrow button to scroll to the Battery window. 21. Press the Select button. Table E: Default Voltages by Battery Type Batteries should match in chemistry, although many AGM’s and flooded batteries are compatible.
  • Page 16 Absorb Amps. It is recommended to monitor charging while the battery banks are in different states of discharge to get the most accurate Minimum and Maximum Absorb Times. Energy Save Feature Control Blue Sea Systems’ P12 Battery Chargers are designed and tested to comply with California Energy Commission (CEC) efficiency requirements and ship with these settings by default.
  • Page 17: Temperature Parameters

    Absorption Parameters and Timers (continued) 7531 AND 7532 BATTE R Y C HAR GE R S Absorption Timer Counter The P12 battery charger uses a counter to determine the amount of time a battery bank should remain in Absorb relative to the Maximum Absorb Time. The Absorb timers counter can be seen in the System Status Screen and also referenced on page 19.
  • Page 18: Equalization

    Equalization 7531 AND 7532 BATTE RY C HAR GER S WARNING Equalization is a user selectable and potentially dangerous charging stage that should not be performed without sufficient knowledge. Personal or property damage may occur if equalization is performed incorrectly. It is highly recommended that you seek professional guidance before performing equalization. Equalization causes off gassing of harmful chemicals inside of the battery.
  • Page 19 Equalization (continued) 7531 AND 7532 BATTE R Y C HAR GE R S To change battery, use the up down arrow buttons to scroll the cursor to the Bat1 window. Press the Select button. 10. Using the left and right arrow buttons, scroll between the three different battery banks connected to the charger.
  • Page 20: Screen Summary

    Screen Summary 7531 AND 7532 BATTE RY C HAR GER S Charger Summary The Charger Summary screen provides data of the battery’s status while the battery charger is operational. Options: Press the History button to view previous charger performance Press the Menu button to view the Configuration Menu How to Get Here: From other screens in the charger, select the Back button.
  • Page 21 Screen Summary (continued) 7531 AND 7532 BATTE R Y C HAR GE R S Temperature Parameters The Temperature Parameters screen indicates the minimum and maximum operating temperature based on the temperature sensor. Read the Temperature Parameters section on page 15 before making any adjustments. Options: Select Units and temperature parameters to adjust.
  • Page 22: Alert Screens And Diagnostics

    In this state, all battery charging Internal Temp Above -18° C will stop. This form of temperature alert can not be corrected by the user. Contact Blue Sea Systems for further information regarding internal temperature sensor alerts.
  • Page 23 Shut off AC power for two minutes, and then restart. If the alert screen persists, shut off AC power and Disconnect AC for 2 mins. then restart contact Blue Sea Systems for further assistance. DC Fuse The DC output fuses have opened. The fuses are user serviceable. Please follow the procedure on Page 8 under the Fuse Failure Maintenance section for details on procedure and replacement fuse ratings.
  • Page 24: Optional Installation

    Integrate the P12 Battery Charger with Blue Sea Systems Automatic Charging Relays to take advantage of Charge Coordination. NOTE: If you have a Blue Sea Systems ACR with Start Isolation, it is possible to take advantage of your P12 charger’s ability to integrate in order to optimize charging of your batteries.
  • Page 25 Optional Installation (continued) 7531 AND 7532 BATTE R Y C HAR GE R S ML-ACR Installation Instructions to Enable Start Isolation* (PN 7620 and PN 7622) Disconnect the black ground wire connected to the ML-ACR wire harness. If present, disconnect all Start Isolation wires connected to the Brown, Green, and Orange wires in ML-ACR wire harness. Connect a wire from the ACR 1 port marked “SI”...
  • Page 26: Warranty And Contact Information

    Register your P12 Battery Charger at bluesea.com/warranty Blue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for any of its products found to be defective in materials or manufacture. P12 Battery Chargers and P12 Remote Displays are warranted for a period of five years from the date of first purchase.
  • Page 27: P12 Charge Management System

    P12 Charge Management System Twin Engine System Functions: AC Amperage, Voltage, and Frequency measurement with alarms AC ELCI Ground Fault Protection AC Source Selection 3 Battery Bank AC Branch Circuit Protection and Switching DC Battery Charger Remote Monitoring and Control DC Amperage and Voltage measurement with alarms DC Branch Circuit Protection and Switching DC Remote Battery Isolation Switching...
  • Page 28 425 Sequoia Drive Bellingham, WA 98226 USA p 360.738.8230 p 800.222.7617 USA and Canada Customer Service conductor@bluesea.com www.bluesea.com 980025140 Rev. 005...
  • Page 29 Ce manuel d'utilisation décrit le produit mentionné dans ce document au moment de sa publication. Les spécifications et les performances sont sujettes à modification à la discrétion de Blue Sea Systems. Pour les révisions les plus récentes de cette publication, visitez bluesea.com/products/12.
  • Page 30 Table des matières C HARGEURS D E BATTERIE 7 531 E T 7532 Instructions de sécurité importantes Vue d'ensemble du chargeur de batteries P12 Spécifications Tableaux d'installation • Tableau A: Taille minimum des câbles recommandés • Tableau B: Protection de circuit c.c. recommandée •...
  • Page 31 N'utilisez aucun dispositif accessoire directement branché au chargeur, à part ceux qui sont fabriqués par Blue Sea Systems et conçus pour être utilisés avec le chargeur de batterie P12. N'utilisez pas le chargeur s'il est tombé ou s'il est endommagé. Contactez Blue Sea Systems qui vous conseillera.
  • Page 32 CONSIGNES DE SÉCURITÉ IMPORTANTES CHARGEURS DE BATTERIE 7531 ET 7532 e) NE JAMAIS fumer et éviter la présence d'étincelles ou de flammes à proximité de la batterie ou du moteur. f) Faire attention pour réduire les risques de chute d'un outil métallique sur la batterie. Il pourrait créer des étincelles ou court-circuiter la batterie ou une autre partie électrique et causer une explosion.
  • Page 33 Ce traitement est optimal pour prolonger la durée de vie des batteries. La coordination de charge s'intègre à la famille de relais de charge automatique (ACR) Blue Sea Systems pour forcer la séparation des groupes de batteries pendant le fonctionnement du P12, pour permettre aux batteries de quitter la phase d'absorption individuellement.
  • Page 34 Vue d'ensemble du chargeur de batterie P12 C HARGEURS DE BATTERIE 7531 E T 7532 Trous de montage Dégagement pour: Fixations de montage M6, 1/4", ou n°12 NOTE: Les centres de vis des trous de montage ne sont pas symétriques. Voir le plan coté...
  • Page 35: Spécifications

    Spécifications CHARGEURS DE BATTERIE 7531 E T 7532 7531 7532 Courant de sortie total (continu) Courant d'entrée c.a. 4,5 A à 115 Vc.a. / 2,25 A à 230 Vc.a. 7,5 A à 115 Vc.a. / 3,75 A à 230 Vc.a. Tension de sortie nominale 12 V c.c.
  • Page 36 Dimensions du produit C HAR GEU RS DE BATTERIE 7531 E T 7532 AVERTISSEMENT Pour assurer la protection contre les intempéries et pour répondre aux exigences ABYC, le chargeur de batterie P12 doit être monté verticalement, selon l'illustration ci-dessous. 7,80" Dégagement pour fixations (198mm) n°12, Ø1/4"...
  • Page 37: Composants Inclus

    Composants inclus CHARGEURS DE BATTERIE 7531 E T 7532 Fixations de chargeur de batterie P12: Vis d'étrier anti-traction c.c. Vis mécaniques à tête cylindrique M3 x 25 mm Couple recommandé: 5–10 in-lb (0,6–1,1 Nm) Vis de couvercle isolant de dispositif anti-traction c.a. Vis mécanique à...
  • Page 38: Fournitures Nécessaires

    Fournitures nécessaires et maintenance CHARGEURS DE BATTERIE 7531 ET 7532 1. Câble c.a. (voir Tableau D page 5) NOTE: La longueur du câble doit permettre de relier le panneau aux raccords c.a. du chargeur de batterie avec un parcours, un support, des boucles d'écoulement, des boucles de service et une terminaison corrects.
  • Page 39 Instructions d'installation et de fonctionnement C HAR GEU RS DE BATTER IE 7531 E T 7532 AVERTISSEMENT Assurez-vous que la zone autour du chargeur et des batteries est bien aérée pendant que les batteries sont en charge. Cet appareil doit être installé dans un endroit sec et bien aéré, sans fixations desserrées.
  • Page 40: Instructions D'installation

    Branchez le câble du/des relais de charge automatique (ACR) à/aux orifice(s) de raccordement ACR. NOTE: Si vous possédez un ACR Blue Sea Systems avec isolement au démarrage, il est possible de profiter de la capacité d'intégration du chargeur de batterie P2.
  • Page 41: Configuration Initiale Du Chargeur

    Configuration initiale du chargeur CHARGEURS DE BATTERIE 7531 E T 7532 Pendant la configuration initiale du chargeur ou après l'avoir réinitialisé aux valeurs par défaut, les écrans suivants ont besoin des instructions de l'utilisateur pour assurer une charge de batterie fonctionnelle. Utilisez le bouton fléché...
  • Page 42: Configuration Avancée Du Chargeur

    Configuration avancée du chargeur CHARGEURS DE BATTERIE 7531 ET 7532 Cette configuration permet de modifier la langue, limiter le bruit du ventilateur, régler le rétroéclairage et limiter la consommation de courant c.a. Appuyez sur le bouton Menu. Appuyez sur les boutons fléchés gauche ou droit pour faire défiler l'écran jusqu'à...
  • Page 43: Réinitialisation Aux Valeurs Par Défaut

    Configuration avancée du chargeur (suite) C HARGEURS DE BATTERI E 7531 E T 7532 19. Après avoir validé les paramètres d'affichage désirés, appuyez sur Back. 20. Appuyez sur le bouton fléché gauche ou droit pour faire défiler l'écran jusqu'à la fenêtre Battery. 21.
  • Page 44 Commande de la fonction d'économie d'énergie Les chargeurs de batterie P12 de Blue Sea Systems sont conçus et testés pour être conformes aux exigences de rendement de la California Energy Commission (CEC) et sont expédiés avec des réglages par défaut.
  • Page 45: Paramètres De Température

    Paramètres et temporisateurs d'absorption (suite) CHARGEURS DE BAT TERIE 7531 E T 7532 Compteur de temporisateur d'absorption Le chargeur de batterie P12 utilise un compteur pour déterminer la durée pendant laquelle un groupe de batteries doit rester dans la phase d'absorption par rapport au temps d'absorption maximum.
  • Page 46: Égalisation

    Égalisation C HARGEURS DE BATTERIE 7531 E T 7532 AVERTISSEMENT L'égalisation est un état de charge sélectionnable par l'utilisateur et potentiellement dangereux, et ne doit pas être effectué sans connaissances suffisantes. Une procédure d'égalisation incorrecte peut entraîner des dommages corporels ou matériels. Il est fortement recommandé de faire appel à un professionnel avant d'effectuer la procédure d'égalisation.
  • Page 47 Égalisation (suite) C HARGEURS DE BATTER IE 7531 E T 7532 Pour changer la batterie, utilisez les boutons fléchées vers le haut vers le bas pour faire défiler le curseur jusqu'à la fenêtre Bat1. Appuyez sur le bouton Select. 10. Utilisez les boutons fléchés gauche et droit pour alterner entre les trois groupes de batteries branchés au chargeur.
  • Page 48: Sommaire Des Écrans

    Sommaire des écrans C HARGE URS DE BATTERIE 7531 E T 7532 Sommaire du chargeur L'écran Charger Summary fournit des données sur l'état de la batterie pendant que le chargeur de batterie fonctionne. Options: Appuyez sur le bouton History pour afficher les performances précédentes du chargeur Appuyez sur le bouton Menu pour afficher le menu de configuration Comment y arriver: À...
  • Page 49 Sommaire des écrans (suite) CHARGEURS DE BAT TERIE 7531 E T 7532 Paramètres de température L'écran Temperature Parameters indique la température minimum et maximum de fonctionnement basée sur le capteur de température. Lisez la section Paramètres de température à la page 15 avant de procéder à des réglages.
  • Page 50: Écrans D'alerte Et Diagnostics

    Si l'écran d'alerte de ventilateur ne s'affiche pas et que le ventilateur semble fonctionner correctement, continuez à utiliser le chargeur de batterie normalement. Si l'écran d'alerte de ventilateur s'affiche, contactez Blue Sea Systems pour obtenir des instructions sur le remplacement du ventilateur.
  • Page 51 Coupez l'alimentation c.a. pendant deux minutes, puis rebranchez-la. Si l'écran d'alerte est toujours Charger is off to prevent damage présent, coupez l'alimentation c.a. et contactez Blue Sea Systems pour toute assistance. Disconnect AC for 2 mins. then restart Fusible c.c.
  • Page 52: Installation En Option

    Intégrez le chargeur de batterie P12 aux relais de charge automatique Blue Sea Systems pour profiter de la coordination de charge. NOTE: Si vous avez un relais ACR Blue Sea Systems avec isolement au démarrage, vous pouvez profiter de la capacité d'intégration de votre chargeur P12 pour optimiser le chargement des batteries.
  • Page 53 Installation en option (suite) C HARGEURS DE BATTER IE 7531 E T 7532 Instructions d'installation ML-ACR pour activer l'isolement au démarrage* (PN 7620 et PN 7622) Débranchez le câble de masse noir relié au faisceau électrique ML-ACR. S'ils sont présents, débranchez tous les câbles d'isolement au démarrage reliés aux câbles marron, vert et orange du faisceau électrique ML-ACR. Branchez un câble entre l'orifice ACR1 marqué...
  • Page 54: Garantie Et Coordonnées

    Les chargeurs de batterie P12 et les afficheurs distants P12 sont garantis pendant une période de cinq ans à compter de la date d'achat initial. Aucune compensation ne sera accordée pour des produits non retournés à Blue Sea Systems pour analyse et aucune compensation ne sera accordée pour la main d’œuvre nécessaire pour remplacer un produit défectueux.
  • Page 55: Système De Gestion De Charge P12

    Système de gestion de charge P12 Moteur double Fonctions du système: Mesure d'intensité c.a., de tension et de fréquence avec alarmes Protection de défaut à la masse c.a. ELCI Sélection de source c.a. Groupe de 3 Protection et commutation de circuit c.c. Contrôle et commande à...
  • Page 56 425 Sequoia Drive Bellingham, WA 98226 USA Tél. 360.738.8230 Tél. 800.222.7617 Service client États-Unis et Canada conductor@bluesea.com www.bluesea.com 980025140 Rév.005...

This manual is also suitable for:

P12 7531P12 7532

Table of Contents