Blue Sea Systems BatteryLINK 7605 User Manual

Blue Sea Systems BatteryLINK 7605 User Manual

10a charger

Advertisement

Available languages

Available languages

Quick Links

User Manual
YEAR
WARRANTY
Read and understand the contents of this User Manual. It contains important safety, handling, and operational instructions for the
BatteryLink ® Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and
performance are subject to change at the discretion of Blue Sea Systems. To view the most current revision of this publication visit
bluesea.com/products/7605.
MULTISTAGE CHARGER
10A CHARGER
7605
INTEGRATED ACR
Scan for
additional
product
information

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BatteryLINK 7605 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blue Sea Systems BatteryLINK 7605

  • Page 1 BatteryLink ® Chargers. This User Manual describes the product mentioned herein at the time of its publication. Specifications and performance are subject to change at the discretion of Blue Sea Systems. To view the most current revision of this publication visit...
  • Page 2: Important Safety Instructions

    5. THE BATTERYLINK® CHARGER IS DESIGNED FOR USE ONLY in a permanent installation aboard a vessel or in a vehicle. It is not intended for use as a portable charger. 6. USE OF AN ATTACHMENT NOT RECOMMENDED OR SOLD BY BLUE SEA SYSTEMS may result in a risk of fire, electric shock, or injury to persons.
  • Page 3: Preparing To Charge

    e. NEVER smoke or allow a spark or flame in vicinity of battery or engine. f. Be cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion. g.
  • Page 4 BATTERYLINK® CHARGER OVERVIEW Charging and ACR status LEDs NOTE: All side terminations 1/4" x 0.032" male quick release DC Output Battery Negative Battery Temperature Sensor Remote LED Start Isolation Mounting holes (3) Clearance for #10 or M5 mounting hardware. Hex recesses accept AC input 6' [1.8m] DC output battery positive connections #10 (3/8"...
  • Page 5 BatteryLink Charger Features ® The BatteryLink Charger is a 120V AC/230V AC nominal input, 12V DC nominal output, 10A battery charger ® with integral battery combiner (ACR) providing a second battery connection, as well as standard ACR function when AC power is not present. •...
  • Page 6: Battery Temperature Compensation

    Battery Temperature Compensation Battery temperature compensation is output voltage regulation based on battery temperature variances. Since batteries can see extreme temperature differences, it is important to regulate output voltage with temperature to maximize battery life. A battery in a cold environment should not be charged at the same voltage as a battery in a hot environment. The BatteryLink®...
  • Page 7: Supplies Needed

    YES, if negative wire is Fuse Required For Negative? < 12 AWG (4 mm²) < 8 AWG (10 mm²) Fuse Type Fuse Holder PN Recommended Blue Sea Systems Fuse PN MRBF Fuse 5191 5176 (40A) 5178 (60A) 5182 (90A) Not Recommended AMI®/MIDI®...
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Before beginning electrical installation, disconnect all positive and negative AC and DC power sources. 2. For optimal performance, mount the charger vertically, in a well ventilated location. NOTE: The charger should be located near the batteries to minimize wire length and its associated voltage drop to maximize charging efficiency.
  • Page 9 QUICK INSTALLATION DIAGRAM Engines with Dual Circuit Plus™ Battery Switch 6011 combined alternator recommended for 7605 BatteryLink® Charger and starter wires - typical of outboard motors FUSE** Accessories BatteryLink® Charger FUSE* BATTERY BATTERY NEG. NEG. Battery Temp Sensor Remote Start Isolation AC Input FUSE*...
  • Page 10: Full Installation Diagram

    FULL INSTALLATION DIAGRAM accessory start 2A FUSE 16 AWG (1.5mm²) START KEY SWITCH Engines with combined alternator Dual Circuit Plus™ Battery Switch 6011 and starter wires recommended for 7605 BatteryLink™ Charger - typical of outboard motors Accessories FUSE** BatteryLink® Charger FUSE* BATTERY BATTERY...
  • Page 11: Dimensioned Drawings

    DIMENSIONED DRAWINGS 84.7mm 3.34in 110.8mm 4.36in 10.6mm .42in 0.0mm THIS VIEW SHOWN WITH COVER REMOVED FOR OPTIMAL PERFORMANCE, MOUNT VERTICALLY AS SHOWN, IN A WELL VENTILATED AREA. RECOMMENDED MOUNTING CLEARANCE 50mm MINIMUM ON ALL SIDES. 11.1mm .44in SERRATED STUD FLANGE NUTS HEIGHT TYP.
  • Page 12: Specifications

    Specifications Nominal Output Voltage 12V DC Total Output Current (25°C) Output Connections 2 positive, 1 negative Universal AC Input Voltage 100V-240V AC Input Frequency Range 50/60 Hz AC Input Current 3.25A @ 100V 1.75A @ 200V Typical Float Voltage (25°C) 13.5V DC Typical Absorption Voltage (25°C) 14.4V DC...
  • Page 13: Manuel D'utilisation

    BatteryLink ® . Ce manuel d'utilisation décrit le produit mentionné dans ce document au moment de sa publication. Les spécifications et les performances sont sujettes à modification à la discrétion de Blue Sea Systems. Pour les...
  • Page 14: Consignes De Securite Importantes

    Blue Sea Systems pour la réparation. NE PAS DEMONTER LE CHARGEUR; Contacter Blue Sea Systems pour la réparation. Un remontage incorrect peut entraîner un risque de choc électrique ou d'incendie. POUR REDUIRE LES RISQUES DE CHOC ELECTRIQUE, débrancher le chargeur de la prise avant de procéder à...
  • Page 15 JAMAIS fumer et éviter la présence d'étincelles ou de flammes à proximité de la batterie ou du moteur. f. Faire attention pour réduire les risques de chute d'un outil métallique sur la batterie. Il pourrait émettre des étincelles ou court-circuiter la batterie ou une autre partie électrique et causer une explosion. g.
  • Page 16 VUE D'ENSEMBLE DU CHARGEUR BATTERYLINK® LED de charge et d'état ACR NOTA: Tous les raccordements latéraux 1/4" x 0,032" à raccord rapide mâle Sortie c.c. Négatif de batterie Capteur de température de batterie LED distante Start Isolation Trous de montage (3) Jeu pour matériel de montage n°...
  • Page 17 Caractéristiques du chargeur BatteryLink ® Le chargeur BatteryLink® est un chargeur de batterie de 10 A ayant une entrée nominale de 120 VCA/230VCA, une sortie nominale de 12 VCC, équipée d'un coupleur de batterie intégré (ACR) qui permet le raccordement d'une deuxième batterie, ainsi qu'une fonction ACR de série lorsque l'alimentation CA n'est pas présente.
  • Page 18 Compensation de température de la batterie La compensation de température de la batterie est le réglage de la tension de sortie basée sur les variations de température de la batterie. Étant donné que les batteries peuvent connaître des différences de température extrêmes, il est important de régler la tension de sortie avec la température pour optimiser la durée de vie de la batterie.
  • Page 19 OUI, si le fil négatif est Fusible nécessaire pour le négatif? < 12 AWG (4 mm²) < 8 AWG (10 mm²) Type de fusible Porte-fusible PN Fusible PN Blue Sea Systems recommandé Fusible MRBF 5191 5176 (40A) 5178 (60A) 5182 (90A) Non recommandé...
  • Page 20: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION Avant de procéder à l'installation électrique, débrancher toutes les sources d'alimentation positives et négatives c.a. et c.c. Pour des performances optimales, monter le chargeur verticalement dans un endroit bien aéré. NOTA: Le chargeur doit être placé près des batteries pour minimiser la longueur de câble et la baisse de tension associée afin de maximiser le rendement de la charge.
  • Page 21 SCHEMA D'INSTALLATION RAPIDE Moteurs avec fils Interrupteur de batterie 6011 Dual Circuit Plus™ d'alternateur et de recommandé pour le chargeur BatteryLink® 7605 démarreur combinés - typiques des moteurs hors-bord FUSIBLE** Accessoires Chargeur BatteryLink ® FUSIBLE* BATTERY BATTERY NEG. NEG. Battery Temp Sensor Remote...
  • Page 22 SCHEMA D’INSTALLATION PLEIN accessoire marche éteint démarrage FUSIBLE 2 A 16 AWG (1,5 mm²) INTERRUPTEUR DE DÉMARRAGE A CLÉ Moteurs avec fils d'alternateur et de Interrupteur de batterie 6011 Dual Circuit Plus™ démarreur combinés recommandé pour le chargeur BatteryLink® 7605 - typiques des moteurs hors-bord Accessoires...
  • Page 23 PLANS COTES 84,7mm 3,4” 110,8mm 4,36” 10,6mm ,42” 0,0mm 0” VUE AVEC COUVERCLE DEPOSE POUR DES PERFORMANCES OPTIMALES, MONTER VERTICALEMENT COMME INDIQUE, DANS UN ENDROIT BIEN AERE. DISTANCE DE MONTAGE RECOMMANDÉE 175 mm MINIMUM SUR TOUS LES CÔTÉS HAUTEUR DE GOUJON ÉCROU À...
  • Page 24: Spécifications

    Spécifications Tension de sortie nominale 12 V C.C. Courant de sortie total (25 °C) Raccordements de sortie 2 positifs, 1 négatif Tension d'entrée CA universelle 100 V-240 V CA Plage de fréquence d'entrée 50/60 Hz Courant d'entrée c.a. 3,25 A à 100 V 1,75 A à...

Table of Contents