Compaq P700 Service Manual page 15

Hide thumbs Also See for P700:
Table of Contents

Advertisement

4-7. Digital Convergence Adjustment
Convergence (Low) Mode
1. Adjust the H.STAT and V.STAT with "HSTAT" and
"VSTAT".
A. Horizontal Convergence
YBH-T-LO
9
CBH-T-L-LO
17
MBH-T-L-LO
1
APH-L-LO
19
MBH-B-L-LO
11
CBH-B-L-LO
YBH-B-LO
Adjust each misconvergence point in sequence.
B. Vertical Convergence
V STAT-T-LO
13
CCV-T-L-LO
21
MCV-T-L-LO
3
XBV-L-LO
23
MCV-B-L-LO
CCV-B-L-LO
15
V STAT-B-LO
Adjust each misconvergence point in sequence.
2. Repeat the procedure of A and B so that the conver-
gence of the entire screen is within the specification.
Convergence (High) Mode
1. Adjust the H.STAT and V.STAT with "HSTAT-HI" and
"VSTAT-HI".
Horizontal Convergence
YBH-T-HI
9
CBH-T-L-HI
17
MBH-T-L-HI
1
APH-L-HI
19
MBH-B-L-HI
11
CBH-B-L-HI
YBH-B-HI
Adjust each misconvergence point in sequence.
10
5
CBH-T-R-LO
18
MBH-T-R-LO
2
APH-R-LO
HSTAT
20
MBH-B-R-LO
12
CBH-B-R-LO
6
14
7
CCV-T-R-LO
22
MCV-T-R-LO
4
XBV-R-LO
VSTAT
24
MCV-B-R-LO
16
CCV-B-R-LO
8
10
5
CBH-T-R-LHI
18
MBH-T-R-HI
2
APH-R-HI
HSTAT-HI
20
MBH-B-R-HI
12
CBH-B-R-HI
6
— 15 —
Vertical Convergence
Adjust each misconvergence point in sequence.
2. Repeat the procedure of A and B so that the conver-
gence of the entire screen is within the specification.
4-8. Convergence Specification
C
B
A
312 mm
P700
A Zone:
Primary Mode
Others
H: < 0.25mm
H: < 0.3mm
V: < 0.25mm
V: < 0.3mm
B Zone:
Primary Mode
Others
H: < 0.3mm
H: < 0.4mm
V: < 0.3mm
V: < 0.4mm
C Zone:
Primary Mode
Others
H: < 0.35mm
H: < 0.4mm
V: < 0.35mm
V: < 0.4mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents