Solenoid Shifted Air
distribution Valve Option
Warren Rupp's solenoid shifted, air distribution valve option utilizes electrical
signals to precisely control your SANDPIPER's speed. The solenoid coil is
connected to a customer - supplied control. Compressed air provides the pumping
power, while electrical signals control pump speed (pumping rate).
Operation
The Solenoid Shifted SANDPIPER has a solenoid operated, air distribution valve
in place of the standard SANDPIPER's pilot operated, air distribution valve.
Where a pilot valve is normally utilized to cycle the pump's air distribution valve,
an electric solenoid is utilized. As the solenoid is powered, one of the pump's air
chambers is pressurized while the other chamber is exhausted. When electric
power is turned off, the solenoid shifts and the pressurized chamber is exhausted
while the other chamber is pressurized. By alternately applying and removing
power to the solenoid, the pump cycles much like a standard SANDPIPER
pump, with one exception. This option provides a way to precisely control and
monitor pump speed.
Before Installation
Before wiring the solenoid, make certain it is compatible with your system voltage.
*Special Conditions For Safe Use
A fuse corresponding to its rated current (max. 3*I
motor protecting switch with short-circuit and thermal instantaneous tripping (set to rated
current) shall be connected in series to each solenoid as short circuit protection. For
very low rated currents of the solenoid the fuse of lowest current value according to
the indicated IEC standard will be sufficient. The fuse may be accommodated in the
associated supply unit or shall be separately arranged. The rated voltage to the fuse shall
be equal to or greater than the stated rated voltage of the magnet coil. The breakage
capacity of the fuse-link shall be as high as or higher than the maximum expected short
circuit current at the location of the installation (usually 1500 A). A maximum permissible
ripple of 20% is valid for all magnets of direct-current design.
19
• Model S05 Metallic
41
3rd Terminal
for ground
13
39
according IEC 60127-2-1) or a
rat
33
28
40
43
4
22
Solenoid Shifted Air Valve Parts list
(Includes all items used on Composite Repair Parts List except as shown)
Item
Part Number
4
114.023.157
114.023.551
114.023.559
39
893.099.000
40
219.001.000
219.004.000
219.002.000
219.003.000
41
241.001.000
241.003.000
42
171.065.115
43
618.050.150
For Explosion Proof Solenoid Coils used in North America and
outside the European Union.
40
219.009.001
219.009.002
219.009.003
219.009.004
219.009.005
219.009.006
note:
Item 41 (Conduit Connector) is not required
*
For ATEX Compliant Solenoid Coils used in the European Union
40
219.011.001 Solenoid Coil, Single mounting
219.011.002 Solenoid Coil, Single mounting
219.011.003 Solenoid Coil, Single mounting
219.011.004 Solenoid Coil, Single mounting
note:
Item 41 (Conduit Connector) is not required
Compressed Air Temperature Range: Maximum Ambient Temperature
to plus 50°C
.
www
sandpiperpump
42
8
20
28
43
33
description
Bracket, Intermediate
Bracket, Intermediate
Bracket, Intermediate
(Conductive Polypropylene Midsection ONLY)
Solenoid Valve, NEMA4
Solenoid Coil, 24VDC
Solenoid Coil, 24VAC/12VDC
Solenoid Coil, 120VAC
Solenoid Coil, 240VAC
Connector, conduit
Conduit Connector with
Suppression Diode (DC Only)
Capscrew, Flanged ¼-20 x 1.00
Plug (Replaces Item 7)
IEC EEX m T4
Solenoid Coil, 120VAC 60 H
Solenoid Coil, 240VAC 60 H
Solenoid Coil, 12VDC
Solenoid Coil, 24VDC
Solenoid Coil, 110VAC 50 H
Solenoid Coil, 230VAC 50 H
II 2G EE
II T5
x m c
II 2G EEx m c T5
II 3/2 G E
II T5
x m c
II 2D c IP65 T100°C
II 2D
IP65 T100°c
c
12 VDC, 3.3W / 267mA
24 VDC, 3.3W / 136mA
110/120 VAC, 3.4W / 29mA
220/240 VAC, 3.4W / 15mA
.
com