Operation method-1 :

(A) Turn off the projector. Next, connect the flexible-cables of the LCD panels to the assem-
(B) Set the image to "service mode."
(C) Select Group no. 930-0 (Full lamp mode ) or
(D) Press power on/off button to quit the service mode.
(E) Turn off the projector. Remove the flexible cables of LCD panels from the assembly Main.
Fine adjustment-1
1. Loosen three screws-B on the Integrator lens out unit.
2. Insert a slot screwdriver into slot-A on the Integrator lens out unit, turn it and
decrease Unevenness color.
3. Tighten the three screws B to fix the integrator lens-out unit.
Fine adjustment-2
1. Loosen 2 screws-A on the Integrator lens in unit.
2. Insert a slot screwdriver into slot-C on the Integrator lens in unit, turn it and decrease
Unevenness color.
3. Tighten the 2 screws A to fix the integrator lens-in unit.
bly Main. Turn on the projector.
Select Group no. 930-1 (To light only the "Lamp-1." ) or
Select Group no. 930-2 (To light only the "Lamp-2" )
Check data value on the screen, and go to (1), (2) or (3).
(1) If the data value appears "11" on the screen, go to (a).
(2) If the data value appears "0" on the screen, go to (b).
(3) If the data value appears "99" on the screen, go to (c).
(a) Go to (D).
(b) Set the data value to "10" and go to (D).
(c) Wait until it is changed to "0". Then set the data value to "10" and go to (D).
And turn on the projector.
Integrator lens out
Integrator lens in
-49-