Lap Timing - Bosch DDU 8 Manual

Table of Contents

Advertisement

14.3
Bosch Motorsport
The system is counting:
Outing:
▪ The outing counter is incremented with each power cycle when at least one
valid lap (not by forced lap trigger) was recorded
Lap:
▪ Leaving the pits to lap trigger
▪ Lap trigger to lap trigger
▪ Enforced lap trigger (see Distance based forced trigger)
Fragment:
▪ Test bench operation
▪ Power cycle on track or box (e.g. engine stalled)
▪ File fragmentation size [MB], time [sec]
Channels for display
To display counters use the following channels:
Channel
Laptrigger_outcnt_dls
Laptrigger_lapctr_dls
Fractr
Counting in WinDarab
To automatically name recorded files use filename templates in WinDarab dialog:
Filename template
[outing]
[lap]
[fragment]
[###03] indicates: 'always use 3 digits with leading zeros'.

Lap timing

There are different possibilities to adjust the lap trigger to the timing situation.
The detection time defines the minimum time the input signal changes its state.
E.g. a low active signal needs to be below the threshold for min. 15 ms to release
the trigger.
Channels for display
To display lap times use the following channels:
Channel
Laptrigger_lapctr_dls
Laptrigger_laptime_dls
Laptrigger_laptime_best_dls
DDU 8 Manual
Function
Outing counter
Lap counter
Fragment counter
Function
Value of outing counter
Value of lap counter
Value of fragment counter
Function
Number of completed laps
Running laptime
Laptime of best lap
Lap Trigger | 14