Tools & Materials; Rs-Vs Layout - RBI UL 2703 Installation Manual

Roof mount solution
Table of Contents

Advertisement

T O O L S & M A T E R I A L S
Required Tools for Mounting RBI Solar RS-VS assembly
• Socket wrench
• Torque wrench , 0-10 ft-lbs
• 13 mm hex deep socket
Notes:
1. Do not use power tools for installation when a
torque value is required.
2. All hardware necessary for installation is
provided by RBI Solar.
R B I S O L A R R S - V S L A Y O U T
1
2
*
Most PV module manufacturers have specific
locations or zones where top-down clamps can be
installed. Typically, this zone falls within 1/8 and
1/4 the length of the module.
* *
In order to allow for thermal expansion in the
system,
should not exceed 40 ft. or a run of 12
5
modules. After 12 modules (or 40 ft.), there must
be a break in the rail without a splice.
RBI Solar RS-VS | IG 2017
5
3
Recommended Tools & Materials
• Cutoff saw (excess rail)
• Nail pry-bar (flashing beneath shingles)
• Drill bit - 1/4" (pilot hole)
• Digital laser stud finder
• Tape measure, level & chalk
Plan the layout of the components per the
dimensions below:
1
Approximately 2/3 to 3/4 of the module length (please
refer to module manufacturer's specifications)*
2
For L-foot spacing, please refer to the RBI Solar RS-VS
Design Guide. Note that at least one L-foot should be
4
placed near each splice connection.
3
1½" minimum to allow for end clamp attachment
4
Quantity of modules in the vertical direction x (module
length + 0.75")
5
Quantity of modules in the horizontal direction x (module
Length + 0.75") + 3"(min.)**
1/4 L
1/8 L
L
4"
1.5"
1"
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents