Applicable Roof Types; Flashing Method - RBI UL 2703 Installation Manual

Roof mount solution
Table of Contents

Advertisement

A P P L I C A B L E R O O F T Y P E S
The RBI Solar RS-VS mounting system can be mounted to any roof type with the proper flashing method. Most code
compliant flashing methods are compatible with the RBI Solar RS-VS system's L-foot. The roof covering will dictate the
proper flashing method. Common roofing types are:
Asphalt Shingle
The RBI Solar RS-VS mounting system carries a Class A Fire Rating under UL 1703 on steep-sloped roofs when used with
all Type 1, Type 2, and Type 3 modules per testing performed by Intertek. It is important to check the following items
prior to installation on the roof:
• Verify roof rafter size, material, and span to ensure that the roof structure is sound and capable of supporting
the additional load of the PV array within local climatic conditions (wind/snow loads).
• Measure roof surfaces and account for any obstacles such as chimneys, parapets, skylights, or roof vents.
• Confirm roof construction, type, and condition is suitable to last the life of the product.
• Confirm that the roof is fire resistant and rated for the application.
• Account for any roof access areas and required municipal set-back distances following the local jurisdiction.
F L A S H I N G M E T H O D S
Note: The components in this section were not evaluated by UL since they are not on the grounding path.
RBI Solar RS-VS Flashing Set with Lag Bolt
This code-compliant flashing set is used for residential or
commercial (wood structure) applications of asphalt shingles. This
set can be purchased from RBI Solar with either black or mill finish
flashing plates.
RBI Solar RS-VS | IG 2017
Standing-Seam
Curved Tile
Slate Tile
Trapezoidal
Lag Bolt
Flat Washer
Bonded Washer
RSA-CP-SQ
Square Adapter
EcoFasten GF1-BLK-0812
Flashing Plate
Membrane
4