Instruction Manual CBS-Series Cosel Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: FORTEC Elektronik AG Hauptniederlassung Lechwiesenstr. 9 86899 Landsberg am Lech Telefon: +49 (0) 8191 91172-0...
Page 2
Model Circuit method current Single Double Series Redundancy input fuse protection Material [kHz] operation operation sided sided CBS50 Forward converter Aluminum CBS100 Forward converter Aluminum Refer to CBS200 Forward converter Aluminum table No.1 CBS350 Forward converter Aluminum CBS450 Forward converter Aluminum Refer to Instruction Manual.
Page 3
DC-DC Converters Bus Converter . Power Module Type Instruction Manual Pin Confi guration CBS-14 Connection for Standard Use CBS-14 Wiring Input/Output Pin CBS-14 Wiring input pin CBS-14 Wiring output pin CBS-15 Function CBS-16 Overcurrent protection CBS-16 Overvoltage protection CBS-16 Thermal protection CBS-16 Remote ON/OFF CBS-16...
Cin : External capacitor on the input side Remote ON/OFF Co : External capacitor on the output side : Primary decoupling capacitor No connection (CBS350/450) CASE Wiring base plate (CBS50/100/200) Fig.2.1 Connection for Standard Use -VIN -DC input +VOUT +DC output...
Page 5
To protect the power module from tion (Fig. 2.1). reversed polarity voltage, installing an external diode as shown in Fig. 3.3 is recommended. Capacitance CBS50/100/20024:at least 68 F CBS35024:at least 220 FX2 CBS50/100/20048:at least 33 F CBS35048:at least 68 FX2 +VIN...
Page 6
Note that devices inside the power module may fail when a volt- age greater than the rated output voltage is applied from an exter- 50mm CBS50/100/200 nal power supply to the output terminal of the power module. This Measuring board could happen in in-coming inspections that include OVP function test or when voltage is applied from the load circuit.
Page 7
¡ Output voltage between +VOUT and -VOUT can be adjusted by too high may cause OVP to work. connecting external resistors to TRM. However, when the input voltage is 18 - 20VDC with CBS50/100/ 20024 or 36 - 40VDC with CBS50/100/20048, the output voltage +VOUT adjustment range is 60 - 105% of the rated output voltage except Control Amp.
PCB to let it act as a shield and connect this pattern to the 5.1 Series operation CASE pin (CBS50/100/200) or the mounting hole. ¡ When a heat sink cannot be fi xed on the base plate side, order the ¡...
Page 9
DC-DC Converters Bus Converter . Power Module Type Instruction Manual (85.7) (83.3) -VIN -VOUT 1CBS3502412,CBS3502448,CBS3504848 CASE 2 Others (CBS350) +VIN (15) +VOUT (85) 100 110 +VOUT, -VOUT Others Aluminum base plate temperature Tc [C] Less than Less than Less than Less than (75) 39.2N(4kgf)
Page 10
DC-DC Converters Bus Converter . Power Module Type Instruction Manual ¡ Derating curve characteristics with respect to aluminum base plate temperature are shown in Fig. 6.6. Measure the temperature of the base plate in a location away from direct airfl ow (A). Note that F-CBS-F1/F2 operation within the hatched areas will cause a signifi...
DC-DC Converters Bus Converter . Power Module Type Instruction Manual 7 Safety Considerations ¡ To apply for safety standard approvals with the power module, the following conditions must be met. Consult us for more details. The power modules must be used as a component power supply ¿...
Page 12
Our company network supports you w ou worldwide with offices in Germany, Austria, Swit witzerland, Great Britain and the USA. For more information pl n please contact: ORTEC Elektronik AG Haup auptniederlassung Lech echwiesenstr. 9 8689 6899 Landsberg am Lech Telef elefon: +49 (0) 8191 91172-0...