6.4 Reliability Characteristics

6.4
Reliability Characteristics
The test conditions stated below are an extract of the complete test specifications.

Table 16: Summary of reliability test conditions

Type of test
Conditions
Vibration
Frequency range: 10-20Hz; acceleration: 3.1mm
amplitude
Frequency range: 20-500Hz; acceleration: 5g
Duration: 2h per axis = 10 cycles; 3 axes
Shock half-sinus
Acceleration: 500g
Shock duration: 1msec
1 shock per axis
6 positions (± x, y and z)
Dry heat
Temperature: +70 ±2×C
Test duration: 16h
Humidity in the test chamber: < 50%
Temperature
Low temperature: -40×C ±2×C
change (shock)
High temperature: +85×C ±2×C
Changeover time: < 30s (dual chamber system)
Test duration: 1h
Number of repetitions: 100
Damp heat cyclic
High temperature: +55×C ±2×C
Low temperature: +25×C ±2×C
Humidity: 93% ±3%
Number of repetitions: 6
Test duration: 12h + 12h
Cold (constant
Temperature: -40 ±2×C
exposure)
Test duration: 16h
XT65_XT75_HO_v00.130
Confidential / Preliminary
Page 32 of 67
s
Standard
DIN IEC 68-2-6
DIN IEC 68-2-27
EN 60068-2-2 Bb
ETS 300 019-2-7
DIN IEC 68-2-14 Na
ETS 300 019-2-7
DIN IEC 68-2-30 Db
ETS 300 019-2-5
DIN IEC 68-2-1
2006-10-12