Installation Diagram; Installation Of The Outdoor Unit - Daikin FTS20JEV1K Installation Manual

410a split series
Table of Contents

Advertisement

Indoor unit
Front panel
50mm or more from walls
(on both sides)
Titanium apatite photocatalytic
air-purifying fi lter (2)
Titanium apatite photocatalytic
air-purifying fi lter
Filter frame
The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruction to
the smooth air fl ow. Please follow the installation clearances
shown in the fi gure. Select the coolest possible place where
intake air temperature is not greater than the outside air
temperature (please refer operating range).
Installation clearances
Dimension
Minimum Distance,
mm (in)
Note: If there is any obstacle higher than 2m, or if there is any
obstruction at the upper part of the unit, please allow more
space than the fi gure indicated in the above table.

INSTALLATION DIAGRAM

M4 x 12L
Air fi lter
Air fi lter
Tab
Outdoor Unit

INSTALLATION OF THE OUTDOOR UNIT

A
B
C
300
1000
300
(11.8)
(39.4)
(11.8)
30mm or more from ceiling
Service lid
Opening service lid
Service lid is opening/
closing type.
Opening method
1) Remove the service lid
screws.
2) Pull out the service lid
diagonally down in the
direction of the arrow.
3) Pull down.
D
500
(19.7)
4
Caulk pipe
Cut thermal insulation pipe to
hole gap
an appropriate length and wrap
with putty.
it with tape, making sure that
no gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe with the
fi nishing tape from bottom to top.
A
B
C
D