Diagnostics And Repair - VideoRay PRO 4 Maintenance Manual

Underwater remotely operated vehicle
Hide thumbs Also See for PRO 4:
Table of Contents

Advertisement

Diagnostics and Repair
Are you having a bad day with your Pro 4? You have come to the right place.
Solving problems requires either a methodical diagnostics approach, or lots of luck. If you don't like to gamble, the following may help you
overcome challenges that inevitably present themselves from time to time.
Before providing the specific details of diagnosing and repairing the Pro 4, some basic troubleshooting guidelines are in order. Following these
practices should make your efforts much more efficient and successful.
Suspect and check the obvious first ­ It's easy to get distracted and overlook something obvious.
Recheck the obvious ­ Have someone verify your work. If you're helping someone, verify what you've been told. Sometimes, just talking
through the details can help you realized you missed a step or fact.
Understand correct operation and expected results ­ How should it work and what should happen? Does it?
Learn and recognize symptoms ­ What are the results telling you? What are the most likely suspects and what can be ruled out?
Isolate, Divide and Conquer ­ Classify the problem to sub­systems, remove what you can and substitute known working parts if possible.
Or, try suspect parts with a known working system.
One step at a time ­ Be logical and make each test provide results you can use to narrow down the problem.
The Pro 4 is a collection of relatively simple components, but when something goes wrong, it's easy to get overwhelmed. The following steps
should be your first response to a general system malfunction, especially if the power and communications warning indicators in the ROV Health
instrument are lit.
1.  Power down the system, check the connections and restart using the recommended procedures.
2.  USB problems can be the root of several basic system malfunctions. Disconnect the USB cable from the back of the computer, wait a few
seconds and then reconnect it. Sometimes the USB controller can be locked up. Try connecting the USB cable to a different port on the
computer or rebooting the computer.
3.  To identify whether the tether is a possible source of the problem, connect the ROV directly to the control panel to see if the symptoms
persist.
4.  Remove all attached accessories to eliminate the possibility that an accessory is the source of the problem.
If the problem is more isolated to a specific function, or these steps fail to resolve a general problem, it's time for a closer look at the symptoms and
subsystems.
Sub­System Diagnostics
Power
Communications
Control
Controller
Video
Diagnostics and Repair ­ System Start Up
When VideoRay Cockpit starts up, it checks the hardware configuration to detect three required items:
Video Interface
Communications Interface
Hand Controller
If any of these items are not detected, VideoRay Cockpit will display an error message and will not operator correctly until the configuration issues
are corrected.
Diagnostics  
Pro 4 Maintenance Manual, Novice 1.00.00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents