Sony LDP-1500P Service Manual page 26

Disc
Table of Contents

Advertisement

• The air in the rack should be circulated from the bottom to the top
as indicated.
• The temperature in the rack should not be over 35°C (95°F).
• Allow at least 5 cm(2 inches) behind the rack when installing it against
the wall.
• The distance between each shelf should be at least 40 cm (15
3 /4
inches).
• The holes located at the back of the rack should have filters to pre-
vent dust from being drawn into the rack.
• At least two ventilation fans should be used and should be installed
in the back of the rack as indicated in the figure.
• If a monitor is installed in the same rack, care should be taken to pre-
vent the heat from the monitor affecting the players.
Recommended ventilation when installed in a standard 19" rack
• Use the optional RMM-201 B rack mount kit to install the player(s) in
a standard 19" rack.
• Three ventilation fans with flux 3 m
3
/min should be used for five
players installed in a standard 19" rack. If you have any questionare
regarding ventilation in a rack, consult your authorized Sony
representative.
Note
When the player is used in a dusty place, powdery dust will be drawn
in the player and contaminate the objective lens in the optical pick-up
system. Ask your nearest Sony service facility for lens cleaning.