7.3 Wiring
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a properly rated circuit breaker
(Fuse rating must be rated for the pump used in the system. Check the pump installation manual for the specific fuse size).
WARNING: Improper wiring can cause a fire resulting in injury or death.
NOTE: Switch off the power prior to making connections. Suggested wiring information is given as a guide only. For full
information, refer to the USCG, ABYC and ISO regulations for marine applications and wiring gauges, connectors and fuse
protection.
1.
Follow the wiring diagram (Fig 3). All fuses and the circuit breaker must be properly rated for the bilge pump
within the circuit (see pump instruction manual for guidance). The maximum circuit breaker must be is 20 Amps.
NOTE: Do not use thermal circuit breakers with the BE9003(B)/BE9006(B). Magnetic breakers must be used.
2.
The wiring is as follows:
Manual terminal directly to
brown (+) pump wire.
Automatic terminal to switch
brown/white stripe (+)
Switch brown (-) to pump
brown (+).
Black (-) pump wire to
negative battery terminal
3.
Make all wiring connections above highest water level, using permanent waterproof terminals. Coat terminals with
liquid electrical tape.
7.4 Testing
1.
After installation, hold fingers for 10 seconds on two raised circles on switch face.
NOTE: BE9006(B) has a longer override delay of 30 seconds past the 1/2" (13mm) OFF point.
2.
Test with water in bilge to confirm that pump turns on and off properly. If not, reposition
the switch to allow for activation.

8. MAINTENANCE

This Whale® Electric Field sensor is designed to only require minimal maintenance.
WARNING: Ensure that the switch is disconnected from electrics and thats the system is fully drained prior to maintenance.
For Optimal Performance
Ensure the switch is clear of debris.
Keep fuse and wiring connections high and dry.
Annual Checks
Whale® advises that the vessel plumbing system is checked annually for leaks and obstructions. A full boat electrics
check by a marine electrician is also recommended.
Whale® advises testing your switch as per section 7.4 on an annual basis.
Winterizing
Fully drain system for winterising
Magnetic
Circuit
Breaker
12 to 24 V
d.c. Power
Black Wire
If wiring is correct, pump activates.
Remove top finger, pump stays on.
Remove bottom finger, pump should turn off after a short delay.
Failure to winterise your system may invalidate the product warranty.
.
3 Way Switch
Automatic
Off
Manual
Waterproof Connector
Above Water Level
Pump Fuse
Brown Wire
Pump
Fig 3 - Wiring instructions
Brown / white stripes wire
Brown wire
2" (51mm) ON
Mounting Block
3/8" (10mm)
1/2" (13mm) OFF
3/8" (10mm) min. Mounting Plate
Fig 4 - Testing Switch
Test Circle

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be9006(b)

Table of Contents