Maintenance; Service Support Details; Eu Declaration Of Conformity; Warranty - Whale WU7207 Operating Instructions Manual

In-line pressure switch
Hide thumbs Also See for WU7207:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Option 1: In-Line Pressure Switch Fitted With In-Line Electric Pump
Step 1 Disconnect power supply at the isolator switch.
Step 2 Open one cold tap fully.
Step 3 Ensure that the storage tank is fi lled to a level higher than the pump.
Step 4 Turn the power back on at the isolator switch and close the tap once water is running.
Option 2: In-Line Pressure Switch Fitted With Internal Submersible Pump
Step 1 Ensure that there is no air trapped in the pump. Air is released by gently shaking the pump under water while the pump is in the water tank is switched off .
Trapped air in the submersible will not allow the pump to prime.
Option 3: In-Line Pressure Switch Fitted With External Submersible Pump
Step 1 The pump must be placed in the water before connecting to the side of the vehicle.
Please note: At normal fl ow rates the pump should operate continuously - but at low rates the pressure switch will cycle on and off to maintain back pressure in the
pipework.
Please note: When battery voltage is stable, the pump will produce steady water fl ow. If battery voltage decreases or increases water fl ow will be intermittent and the
pressure switch will turn on and off to maintain pressure in pipework.
Whale recommends regular inspection with maintenance and replacement of components as necessary.
Replacement components are available (Whale Part Number: AK7209).
Setting the Pressure Switch
Your pressure switch is factory set and should not normally require adjustment. However, adjustment may be required if the power supply voltage has varied from the
previous setting, either due to battery drainage or higher voltage being supplied when the battery charger is operating. In the event that your pump doesn't switch off
when you close the taps, or it pulses on and off rapidly when the taps are fully open, follow these guidelines to re-adjust the pressure switch setting.
Step 1 Ensure the system, (including the Water Heater, if installed) is full of water and all taps are closed.
Step 2 Tighten the adjusting screw clockwise until the pump comes on (see Fig. 2).
Step 3 Open any tap until you have a smooth fl ow of water, then close the tap.
Step 4 Return to the pressure switch and turn the pressure switch adjustment screw slowly anti-clockwise until the pump has stopped. Turn the adjustment screw a
further half turn (180 degrees) anti-clockwise.
Step 5 Check for correct operation by opening and closing all taps individually. The pump should turn on when the cold tap is opened and switch off immediately when
the cold tap is closed. There will normally be some pulsations at low fl ows. Please note: The hot side (if applicable) may take up to 10 seconds to react.
Three Golden Rules:
1. Never allow the pump to run dry.
2. Never allow the pump to run continuously for more than 15 minutes.
3. The pump assembly must be unplugged before putting the pump back into the refi lled water container.
6.

MAINTENANCE

Whale recommends regular inspection with maintenance and replacement of components as necessary. Replacement components are available (Whale Part Number:
AK7209).
7.

SERVICE SUPPORT DETAILS

For installation or serviceable parts advice please contact Whale Customer Support:
Tel: 00 44 (0)28 9127 0531
8.

EU DECLARATION OF CONFORMITY

Declaration Number: EU-MSE035-00
We the undersigned:
Name of Manufacturer:
Munster Simms Engineering Ltd
Address:
2 Enterprise Road, Bangor, Co. Down, BT19 7TA
Country:
Northern Ireland
Declare under our sole responsibility that the following apparatus:
Product Description:
Inline Pressure Switch
Model Name and No.:
see table
Brand Name:
Whale
The following notes conformity with the relevant EU Legislation:
.
Product Code
2011/65/EU RoHS II Directive
98/83/EC
(B) suffi x refers to items available only in bulked pack quantities for high volume production OEM use.
Hereby we declare that the product WU7210B fulfi ls the requirements of the Drinking Water Directive 98/83/EC on the approximation of the laws of the Member States
relating to the quality of water intended for human consumption. Components of which have been tested according to the Guidelines of the Ministry of Health and
Environment (Guideline KTW) and the technical rules of the DVGW (W270) and fulfi l the microbiologic and chemical requirements for the use in mobile drinking water
installations. The metal parts used in these products which are in contact with drinking water, fulfi l the requirements according to DIN 50930-6. Reports for all the
individual components in contact with drinking water, are held in the above fi le number, at the address shown.
Name and position of person binding the manufacturer or authorised representative:
Name: Richard Bovill
Function: Engineering Director
Location: Munster Simms Engineering Ltd, 2 Enterprise Road, Bangor, Northern Ireland BT19 7TA
Date of Issue: 1st September 2016
9.

WARRANTY

This product is protected by a 1 year warranty, for full details of our warranty statement please see enclosed leafl et.
©Copyright Whale® 2018 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE®, is a registered trademark of Munster Simms
Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale's policy is one of continuous improvement and we reserve the right to change specifi cations
without prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information contained in this or any product literature is
guaranteed by the Company and may be subject to change at its sole discretion.
Munster Simms Engineering Ltd.
2 Enterprise Road, Bangor, N. Ireland BT19 7TA
Tel: +44 (0)28 9127 0531
Email: info@whalepumps.com
Email: info@whalepumps.com
Technical File Number: TF-MSE035-00
Drinking Water Directive
www.whalepumps.com
2
WU7207(B)
WU7210(B)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wu7207bWu7210Wu7210b

Table of Contents