Performance - Robertshaw 365A Instruction Manual

Vibraswitch malfunction detector
Hide thumbs Also See for 365A:
Table of Contents

Advertisement

MODEL 365A & E365A
VIBRASWITCH® MALFUNCTION DETECTOR
Gold Contact rating:
DPDT (Table 1 – Designation "G")
0.1 A max, 125-250 VAC, non-inductive;
0.1 A max, 30 VDC, non-inductive;
1 mA min, 24 VDC, non-inductive;
2 mA min, 12 VDC, non-inductive;
5 mA min, 6 VDC, non-inductive
Reset Coil Power:
12 VDC, 1.5 A
24 VDC, 0.5 A
48 VDC, 0.2 A
120 VDC, 0.14 A
120 VAC, 0.3 A
240 VAC, 0.3 A
Maximum Energized Time:
4 minutes
2.4

PERFORMANCE

Vibration Measurement Range:
0 to 4.5g (peak) from 0 to 300 Hz (18,000 RPM) – when horizontally mounted.
0 to 3.5g (peak) from 0 to 300 Hz (18,000 RPM) – when vertically mounted.
Setpoint Range:
0 to 4.5 g
Setpoint Adjustment:
Approximately 1g per turn
Accuracy:
± 5% of full range from 0 to 300 Hz (18,000 RPM)
Operating Temperature Range:
-25°C to +60°C (-13°F to +140°F)
Ambient Temperature Effects:
± 10% / 100°F (55.5°C) max
PAGE 4
INSTRUCTION MANUAL
909GF294

Advertisement

Table of Contents
loading

This manual is also suitable for:

E365a

Table of Contents