MODEL 365A & E365A
VIBRASWITCH® MALFUNCTION DETECTOR

2 Specifications

2.1

Environmental

Housing
Weight
Mounting Location
Enclosure Classification Approved for
Ambient Temperature Limits
Humidity
Shock
2.2

CE PRODUCT CERTIFICATION

Vibraswitch® models with CE (ATEX) Approval are distinguished by the addition of the CE
mark on the Nameplate. The nameplate includes additional information:
Robertshaw Industrial Products, 1602 Mustang Drive, Maryville, TN 37801 = manufacturer's name and address
E365A = the manufacturer's Model Number
Serial number = unique serial number assigned by manufacturer which includes a code for year of construction
IIB+H2 = marking according to Group II
T6 = marking essential for safe use
IP66 = Enclosure Rating
Cert. Nr. DEMKO 05 ATEX 0436069
Essential information for safe use:
1. The equipment temperature code is T6.
2. The ambient temperature range for the equipment is -13°F (-25°C) to +140°F (+60°C).
3. The equipment must be bolted closed before power is applied.
4. All cable entry devices and blanking elements shall be certified in type of explosion protection flameproof
enclosure "d", suitable for the conditions of use and correctly installed
5. Unused apertures shall be closed with suitable blanking elements.
2.3

ELECTRICAL

Standard Contact rating:
SPDT (Table 1 – Designation "A")
7 A max, 460 VAC max, 50/60 Hz non-inductive;
0.5 A max, 120 VDC max. non-inductive;
1 A max, 48 VDC max. non-inductive;
2 A max, 24 VDC max. non-inductive;
5 A max, 12 VDC max. non-inductive.
DPDT (Table 1 – Designation "D")
5 A max, 240 VAC max, 50/60 Hz non-inductive;
5 A max, 30 VDC max, non-inductive
Aluminum Alloy, 356-T6
8 lbs approximately
Indoor or Outdoor, unprotected
Class I, Division 1, Group B, C, & D
Class II, Division 1, Group E, F, & G; Enclosure 4 & 4X
Class I, Zone 1, AEx d IIB +H2 T6; Ex d IIB+H2 T6; IP66
ATEX EEx d IIB+H2 T6 IP66
CE 0539
II 2 G
-13°F to +140°F (-25°C to +60°C)
To 95% RH @ 100°F (+37.8°C), non-condensing
40g @ 11 ms maximum