  • Page 1 INSTRUCTION MANUAL VIBRASWITCH MODEL EURO366G INSTRUCTION MANUAL NUMBER Industrial Products Division 1602 Mustang Drive 909GF299 Maryville, Tennessee 37801 Phone: (865) 981-3100 Fax: (865) 981-3168 http://www.robertshawindustrial.com...
  • Page 2 909GF299 RECORD OF CHANGES Design Engineering Engineer’s Manager’s Approval Revision Brief Description Approval Approval Date Number P. Kronau Brien Evans 30JUL08 96644 Production release Page 2...
  • Page 3: Table Of Contents

    909GF299 TABLE OF CONTENTS SECTION PAGE DESCRIPTION ....................1.1 Description..........................1.2 Model Identification ........................ SPECIFICATIONS....................2.1 Environmental..........................2.2 Performance..........................INSTALLATION ....................3.1 General............................3.2 Mounting............................. 3.3 Space Heater ..........................3.4 Wiring............................3.5 Terminal Block........................... 3.6 Mounting Dimensions ......................OPERATION ....................4.1 Operation ............................
  • Page 4: Idescription

    909GF299 SECTION I DESCRIPTION DESCRIPTION The Vibraswitch, Model EURO 366G, is designed to protect rotating, reciprocating, or similar equipment against serious damage from malfunctions that can be detected as an increase in vibration. A reset and holding coil is provided, in the DC/AC voltage as specified so that accidental shutdowns on start can be prevented.
  • Page 5 909GF299 Table 1 - Switch Contacts Designation Description SPDT - Single Pole, Double Throw load contacts. DPDT - Double Pole, Double Throw load switches. Table 2 - Remote Option Reset Designation Description No Reset Coil Volt DC reset coil voltage Volt DC reset coil voltage Volt DC reset coil voltage Volt AC reset coil voltage...
  • Page 6 909GF299 Table 6 – Enclosure Entrances Designation Description Remarks ¾’’ NPT 6125 entrances. One with ¾’’ NPT Plug See Note 1 Table 7 - Space Heater Designation Description 24 VDC 2 Watt 48 VDC 2 Watt 120 VAC 2 Watt 120 VDC 2 Watt 240 VAC 2 Watt No Space Heater...
  • Page 7: Specifications

    909GF299 SECTION II SPECIFICATIONS ENVIRONMENTAL Housing ..................................Cast Iron Q200 ISO ISO 185 Weight Model CS-INVR366G..................................5,5 Kg Enclosure Classification............................Ex d IIB/CT6-tD A21-IP66 T85°C Group II & Category 2G/2GD Ambient T. -20ºC+40ºC or -40ºC+60ºC Certificate No..................................CESI 03 ATEX 186 Enclosure Protection ......................................
  • Page 8: Installation

    Examine the instrument for possible shipping damages. IMPORTANT: If for any reason it is determined that the equipment should be returned to the factory, please notify the nearest Robertshaw Industrial Products sales representative prior to ship- ment. Each unit must be properly packaged to prevent damage. Robertshaw assumes no responsibility for equipment damaged in shipment due to improper packing.
  • Page 9: External Wiring For Vibraswitch Model Euro 366

    909GF299 R E C O M M E N D E D DIESEL ENGINE - COMPRESSOR UNIT RECOMMENDED RECOMMENDED ENGINE - GEAR- CENTRIFUGAL COMPRES- CENTRIFUGAL PUMP RECOMMENDED RECOMMENDED HORIZONTAL OPPOSED COOLING TOWER FAN RECIPROCATING COMPRESSOR RECOMMENDED RECOMMENDED PUMPING UNIT RECIPROCATING COMPRESSOR “Y” TYPE Figure 3.
  • Page 10: Space Heater

    909GF299 SPACE HEATER In some outdoor installations, it may be necessary to install a space heater to prevent moisture condensation. For Vibraswitches with a SPDT switch (Table 1, Designation A) a small conventional carbon 2 watt resistor should be installed across terminals 6 and 8 in the detector. Proper values are shown in Table 3-1. Space heat- ers cannot be readily installed in the field in Vibraswitches with a DPDT switch (Table 1, Designation D).
  • Page 11: Terminal Block

    909GF299 b. If the Model EURO 366G is to be mounted in unprotected or dusty areas, a dust-tight or water-tight seal should be made at the conduit entrance. c. With all mounting complete, remove cover and insert wires through conduit entrance with sufficient length to reach the terminal block.
  • Page 12: Mounting Dimensions

    909GF299 MOUNTING DIMENSIONS Figure 3-3 Mounting Dimensions for the Vibraswitch, Model EURO 366G Model “CS-INVR366G” Enclosure. Page 12...
  • Page 13: Operation

    909GF299 SECTION IV OPERATION OPERATION The Vibraswitch, Model EURO 366G (Refer to Figure 4-1), is sensitive to vibration in a direction (the sensitive axis) per- pendicular to its mounting base. It contains a vibration detecting mechanism, which also functions as a “mechanical am- plifier”, to activate a snap-action switch when the selected level of vibration is exceeded and the detecting mechanism “trips”.
  • Page 14: Adjustment Of Operating Setpoint

    It is agreed that this method can lead to differences in the classification of degree of vibration between individual ob- servers. It is Robertshaw’s contention, and experience bears out this conclusion, that if the machine is operating satisfac- torily as previously defined and the acceleration as measured by the Vibraswitch is within certain limits, the settings as outlined in the instructions will offer protection to the machine and prevent catastrophic failure.
  • Page 15: Setpoint Adjustment

    909GF299 Normal G-Level Measurement With the machine (equipment) operating, back off the Setpoint adjusting screw one turn CCW and reset. If it will not reset, back off the Setpoint adjusting screw two turns CCW, etc. Again turn the Setpoint adjusting screw slowly clockwise until actuation occurs.
  • Page 16: Setpoint Alarm Settings

    909GF299 MINIMUM SETPOINT SETTING (Maximum protection for machine) OPTIMUM SETPOINT SETTING (Good protection for machine) MAXIMUM SETPOINT SETTING (Minimum protection for machine) Z E R O P O I N T FINAL SETPOINT SETTING (G) Example: If the Normal G-Level (a) is 2.8 g above the Zero Vibration Level, the Final Setpoint Setting (b) should be set at 3.5 g above the Zero Vibration Level.
  • Page 17: Vmaintenance

    909GF299 SECTION V MAINTENANCE TROUBLESHOOTING Vibraswitches do not normally require any maintenance or repair, however, listed below are some of the possible mal- functions that may occur and their recommended solutions (Ref. Figure 4-1). Perform all tests with field wiring discon- nected.
  • Page 18 909GF299 c. Unable to Adjust Setpoint Setting to Obtain Tripping Improper air gap between Hold-down (lower) Magnet and Armature. Return the Vibraswitch to the factory for repair. d. Switch Does Not Actuate Defective or improperly adjusted switch - (Ref. Figure 4-1). Manually move the Armature between the hold down magnet (armed position) and latching magnet (latched position) and listen for an audible click of the switch.
  • Page 19: Atex

    909GF299 SECTION VI SPECIAL ATEX INSTRUCTIONS ATEX INSTRUCTIONS Page 19...
  • Page 20 909GF299 Page 20...
  • Page 21 909GF299 Page 21...