ROHO DRY FLOATATION Wheelchair Cushions Operation Manual
Cleaning and Disinfecting
Cleaning and disinfecting are separate processes. Cleaning must precede disinfection. Before use
by a different individual: clean, disinfect, and check product for proper functioning.
Cover Care: Remove hook fastener pieces from bottom of cover prior to cleaning and disinfecting.
Wash with like colors.
To Clean the Cover: Remove the cover. Machine wash in cold water (30°C) with
mild detergent, gentle cycle, or wipe clean with neutral detergent and warm water.
Tumble dry low.
To Disinfect the Cover: Hand wash in cold water
(30°C) using 1 part household liquid bleach per 9
parts water. Keep the product wet with the bleach
solution for 10 minutes, then rinse thoroughly. Or machine wash in hot water (60°C). Tumble dry low.
Follow the safety guidelines on the bleach container.
Cushion Care Cautions: Valve(s) must be closed. DO NOT allow water or cleaning solution to
enter the cushion. DO NOT machine wash or sanitize the cushion or machine dry the cushion. Use
of the following may cause damage to the cushion: abrasives (steel wool, scouring pads); caustic,
automatic dishwasher detergents; cleaning products that contain petroleum or organic solvents,
including acetone, toluene, Methyl Ethyl Ketone (MEK), naphtha, dry cleaning fluid, adhesive remover;
oil-based lotions, lanolin, or phenolic-based disinfectants; ozone gas; ultraviolet light cleaning
methods.
To Clean the Cushion: Remove the cover, close valve(s) and place in a large sink. Hand wash, using
mild liquid hand soap, hand dishwashing liquid, laundry detergent, or a multipurpose detergent
(Follow product label instructions.) Gently scrub all cushion surfaces, using a soft plastic bristle
brush, a sponge or a cloth. Rinse with clean water. Air dry. DO NOT expose to direct sunlight.
To Disinfect the Cushion: Repeat cleaning instructions, using 1 part household liquid bleach per
9 parts water. Keep the product wet with the bleach solution for 10 minutes. Rinse thoroughly with
clean water. Air dry.
Note: Most germicidal disinfectants are safe if used following the disinfectant manufacturer's
dilution directions.
Follow the safety guidelines on the bleach container.
Note About Sterilization: High temperatures accelerate aging and will damage the product
assembly. ROHO products are not packaged in a sterile condition, nor are they intended or required
to be sterilized prior to use. If institution protocol demands sterilization: First, follow the cleaning
and disinfecting instructions; then, open the inflation valve and use the lowest possible sterilizing
temperature, but not to exceed 60°C (158°F), for the shortest time possible. DO NOT autoclave.
Disposal
The components of the products in this manual are associated with no known environmental
hazards when properly used and when disposed of in accordance with all local/regional regulations.
Incineration must be performed by a qualified, licensed waste management facility.
Limited Warranty
Limited Warranty Term from the date the product was originally purchased: SELECT Cushions: 36 months;
All other DRY FLOATATION Products: 24 months. The warranty does not apply to punctures, tears, burns, or
misuse, nor does it apply to the removable cover. See also the ROHO Limited Warranty supplement provided
with your product, or contact Customer Care.
+
30C
1:9
10
30C
or
Need help?
Do you have a question about the DRY FLOATATION and is the answer not in the manual?
Questions and answers