Before Installation - EcoSpring ES300 Installation & Owner's Manual

All in one type air-source heat pump water heater
Hide thumbs Also See for ES300:
Table of Contents

Advertisement

by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
● If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person.
● DISPOSAL: Do not dispose this product as
unsorted municipal waste. Collection of such
waste separately for special treatment is neces-
sary. Do not dispose of electrical appliances as
unsorted municipal waste, use separate collec-
tion facilities. Contact your local government for
information regarding the collection systems
available.
CAUTION
● The earthing pole of socket must be well grounded, make sure
that power supply socket and plug are dry and connected tightly.
● Before cleaning, be sure to stop the operation and turn the
breaker off or pull out the power plug. Otherwise, an electric
shock and injury may be caused.
● Water temperature over 50℃ can
cause severe burns instantly or
death from scalds. Children,
disabled and elderly are at
highest risk of being scalded.
Feel water before bathing or
showering. Water temperature
limiting valves are required as
● Do not operate the unit with a wet hand. An electric shock may
be caused.
● The installation height of power supply should be over 1.8m, if
there is any water exposure, steps must be taken to separate
the power supply from water.
well as an isolation value.
during operation. But, if there is a large volume of water, call
your service agent for instructions. After long term use, check
the unit base and fittings. If damaged, the unit may sink, resulting
in injury. Arrange the drain pipe to ensure smooth draining.
Improper drainage work may cause wetting of the building,
furniture etc. Do not touch the inner parts of the controller or
remove the front panel. Some parts inside are dangerous to
touch, and damage may be caused.
● Do not turn off the power supply.
System will stop or restart heating automatically. A continuous
power supply for water heating is necessary, except service
and maintenance.

3. BEFORE INSTALLATION

3.1 Unpacking
3.1.1 Accessories
Accessory Name
Qty. Sharp
Owner's & Installation
1
Manual
Drain pipe for
1
water condensation
3.1.2 How to transport
1) In order to avoid scratching or deforming
the unit surface, apply guard boards
to the contacting surfaces.
No contact of fingers and other things
with the vanes.
Don't incline the unit more than 45°
in moving, and keep it vertical when
installing.
2) This unit is heavy, it needs to be carried by two or more persons,
othewise might cause injury and damage.
3.2 Location requirements
1)
preserved.
2) The air inlet and outlet should be free from obstacles and strong
wind.
3) The base surface should be flat, surface should be inclined no
more than 2° and able to bear the weight of the unit and suitable
for installing the unit without increasing noise or vibration.
4) The operating noise and air flow expelled should not affect
neighbors.
5) No flammable gas nearby.
6) It should be convenient for piping and wiring.
7) If it is installed in indoor space, it might cause indoor temperature
to decrease and noise disturbance, Please take preventive
measures for this.
8) If the unit has to be installed on a metal part of building, make
sure the electric insulation meets the relevant local electric
Table 3-1
Purpose
Installation and use instruction
This manual
Use for draining the condensate
water (Has been connected to
the lower condensate drain port)
Gradient limit>45°
Installation & Owner's Manual
4

Advertisement

Table of Contents
loading

Table of Contents