All in one type air-source heat pump water heater
Hide thumbs Also See for ES300:
Table of Contents

Advertisement

WARNING
This unit is required reliable earthing
before usage, may otherwise result in
death or injury.
This water heater must be installed by a licensed person as required by the Building Code. Only a
licensed person will give you a compliance certificate, showing that the work complies with all the
relevant standards.
Please read and understand this booklet.If you have any questions,please contact our service repre-
sentative on 0800 200 510.
HOT WATER CAN BE DANGEROUS
Warning – Hot water burns. As a safety precaution, young children should always be supervised around
hot water fixtures.
Heat pump water heaters can store water at temperatures that can cause scalding. Water temperatures
over 50°C can scald and care needs to be taken to ensure that injuries do not occur through incorrect
use of your water heater.
As heat pump water heaters can generate water temperatures in excess of 60°C, regulations require
that a tempering valve be fitted to the heater to prevent water temperatures going to the home exceed-
ing a preset safe maximum. The tempering valve must be connected to the hot water outlet line from
the water heater. The valve must be fitted by an authorized plumber at the time of installation or in retro-
fitting to existing systems.
Care should be taken to avoid coming into contact with any pipe work or fixtures associated with the
water heater pipe lines. Under NO circumstances should any 'home handy man' type modifications be
attempted.
• This appliance is not intended for use by persons (including children) with reduced physical sensory
or mental capabilities, or lack of experience and knowledge, that prevents them from using the appli-
ance safely without supervision or instruction. Children should be supervised by a responsible
person for their safety to ensure that they do not play with the appliance.
• DANGER: Failure to operate the relief valve easing gear at least once every six months may result
in the water heater exploding. Continuous leakage of water from the valve may indicate a problem
with the water heater.
• THE INSTALLATION MUST COMPLY WITH THE REQUIREMENTS OF AS/NZS 3500.4, AS/NZS 3000, and
all local codes and regulatory authority requirements. In New Zealand, the installation must conform
to the New Zealand Building Code G12.
The power supply must be protected by an individual circuit breaker at the main electrical supply
switchboard and rated to suit the booster size. The supply to the heat pump water heater can be oper-
ated directly from the switchboard or via a remotely mounted switch or time clock as requested by the
customer. The heater must be provided with a suitable means for disconnecting the power supply.
If you can't make sure that your house power supply is earthed
well, please don't install the unit.
The unit must be installed by a licensed tradesperson and in
accordance with:
• EcoSpring installation instructions.
• AS/NZS 3500.4-"National Plumbing and Drainage Code Hot
Water Supply Systems-Acceptable Solutions".
• AS/NZS 3000-Wiring Rules.
• Local authority regulations.
• NZ Building Code.
• Local Occupational Health and Satety (OH&S) Regulations.