EcoSpring ES300 Installation & Owner's Manual page 20

All in one type air-source heat pump water heater
Hide thumbs Also See for ES300:
Table of Contents

Advertisement

E-HEATER MODE
: In this mode, the compressor and the fan motor will
not run but the electric element work only.
(Water outlet temp. range 38~60℃,running ambient
-30~43℃).
In the E-heater mode, the water above the electric element that
is being heated is approximately 150L.
Defrost during Water-heating
In the Economy and Hybrid Modes, if the evaporator froze
in a cold environment, the system will defrost automatically.
(3~10 min).
Ambient Temperature
The system's operation temperature is within -30~43℃ and
below are the operation temperature for each mode.
Economy Mode: -7~43℃
1)
2)
Hybrid Mode: -30~43℃
3)
E-heater Mode: -30~43℃
Economy mode should be used when the ambient temperature
is between -7 ~43℃. When the ambient temperature is under
-7℃, the energy efficiency would decrease, E-heater mode
should be used in this circumstance.
Mode Selection
Different modes are designed to meet different demand and the
following are recommended selections.
Economy Mode: -7~43℃, continuous hot water demand below
250L (60℃);
Hybrid Mode: -30~43℃, continuous hot water demand between
300L~350L (60℃);
E-heater Mode: -30~43℃, continuous hot water demand around
150L (60℃).
Self-Protection
Self protection starts in the following circumstances:
Air inlet or outlet is blocked; Error Code: P1
The filter is covered with too much dust; Error Code: P2
Incorrect power supply (exceeding the range of 220-240V)
Error Code: P4
When self-protection occurs, the system will stop and begin
self-check, and restart when the problem is resolved; system will
not restart automatically if problem persists, in such case,
contact your installer
When the self-protection happens, the buzzer will buzz every
minute, the ALARM indicator flashes and the display indicates the
error code and water temperature alternatively. Press CANCEL
key for 3 seconds to stop the alarm. Buzzing and flashing stops
when the problem is resolved and error code disappears on the
display.
NOTE
NOTE
NOTE
If the unit fails to restart after self-protection, Switch the power
supply off manually and restart after the error has been resolved.
Water Temperature Display
The temperature on the display is the water temperature in the
upper part of the water tank this is approximately 75L of water
The 6 indicators beside the water temperature on the display
are for the temperature in the lower part of the tank. When the
temperature is higher than 40℃, the blue indicator will light up;
when higher than 50℃, the yellow indicator will also light up;
when higher than 60℃, all three colour indicators (blue, yellow
and red) will light up. When all indicators light up, the water
temperature has reached the set point.
When using water, the temperature of the lower part may
decrease while the upper part still keeps at a high one, and the
system will start heating the lower part. This is normal.
Trouble Shooting
When error code appears on the display or the unit is not
operating, please contact your installer.
When a n error occur, the buzzer will buzz in every minute,
the warning light flashes, the display will indicate the error code
and water temperature alternatively. Press CANCEL button for
3 seconds to stop the alarm.
Restart after a period of disuse over one year
Please follow the draining and filling water instructions on
page 10 to refill the water.
Heat-up Time
08:00:00
07:00:00
06:00:00
05:00:00
04:00:00
03:00:00
02:00:00
-7
-2
2
7
10
15
Ambient Temp(℃)
15--45
15--50
15--55
15--60
20
25
30
35
40
43
Installation & Owner's Manual
19

Advertisement

Table of Contents
loading

Table of Contents