Operation Range; Main Components; Selection Of Location - Daikin EWYQ080DAYN Installation Manual

Packaged air-cooled water chillers
Hide thumbs Also See for EWYQ080DAYN:
Table of Contents

Advertisement

Features
Factory mounted main switch
Factory mounted flow switch and water filter
Read out of refrigerant pressures (high and low) via controller
High (partial load) efficiency
Electronic expansion valve + sight glass with moisture indication
Voltage free contacts
general operation
pump contact
second pump contact for dual pump function
safety + warning signal (normal open or normal closed
contact)
100% capacity signal, full capacity signal
operation circuit 1
operation circuit 2 (only for EWYQ130~250)
Remote inputs
remote on-off
dual setpoint
capacity limitation (different settings possible)
low noise (only for option OPIF)
free cooling signal
fan forced on signal
Changeable analogue inputs
floating setpoint (mA, V, NTC)
additional water temperature measurement (NTC)
Changeable analogue outputs
unit capacity (mA, V)
O
PERATION RANGE
EWYQ080+100 + 180~250
AT
°C
50
45
43
40
35
30
25
21
20
15
10
5
0
-5
-10
-15
-20
OPZL
OPZL
STD
STD
STD
STD
-10
-5
0
5 10
15 15
15
20 25
30
35 4045
50 55
Cooling mode
Heating mode
AT
Ambient temperature
LWT
Leaving evaporator
water temperature
STD
Standard unit
OPIF
Option inverter fans
OPZL
Option glycol application
for leaving evaporator
water down to –10°C
Installation manual
2
EWYQ130+150
AT
°C
50
45
43
40
35
30
25
21
20
15
10
9
5
0
-5
-10
-15
-20
OPZL
OPZL
STD
STD
STD
STD
-10
-5
0
5 10
15 15
15
20 25
30
35 4045
LWT
°C
Pull down operation area
Continuous operation
area
Protect the water circuit
against freezing by
heater tape (OP10) or by
filling up the system with
a glycol solution
Option inverter fans
(OPIF)
M
AIN COMPONENTS
the unit)
1
Evaporator (in cooling
mode) or condenser (in
heating mode)
2
Condenser (in cooling
mode) or evaporator (in
heating mode)
3
Compressor
4
Electronic expansion
valve + sight glass with
moisture indication
5
Discharge stop valve
(optional)
6
Suction stop valve
(optional)
7
Liquid stop valve
(optional)
8
Chilled water in
(Victaulic
9
Chilled water out
(Victaulic
10
Water drain evaporator
11
Air purge
12
Leaving water
temperature sensor (R3T)
13
Entering water
temperature sensor (R2T)
14
Ambient temperature
sensor (R1T)
15
Drier + charge valve
16
Power supply intake
17
Switchbox
Required space around the unit for service and air intake
Centre of gravity
S
ELECTION OF LOCATION
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to
take adequate measures.
Make sure that the unit is not accessible by the general public.
The units are designed either for roof mounting or ground level
mounting and should be installed in a location that meets the
following requirements:
50 55
LWT
1
The foundation is strong enough to support the weight of the unit
°C
and the floor is flat to prevent vibrations and noise generation.
2
The space around the unit is adequate for servicing and the
minimum space for air inlet and air outlet is available (refer to the
paragraph "Description" in the operation manual).
If several units are being installed side by side, the minimum
service space between these must be taken into account.
3
There is no danger of fire due to leakage of inflammable gas.
4
The equipment is not intended for use in a potentially explosive
atmosphere.
5
Ensure that water cannot cause any damage to the location by
adding water drains to the foundation and prevent water traps in
the construction.
6
Select the location of the unit in such a way that neither the
discharged air nor the sound generated by the unit disturb
anyone.
7
Make sure that the air inlet and outlet of the unit are not
positioned towards the main wind direction. Frontal wind will
disturb the operation of the unit. If necessary, use a windscreen
to block the wind.
8
In heavy snowfall areas, select an installation site where snow
will not affect operation of the unit.
(refer to the outlook diagram supplied with
18
Digital display controller
(inside switchbox)
19
Field wiring intake
20
Main isolator switch
21
Transport beam
22
Flow switch
23
Fan
24
Safety valve
25
High pressure sensor
26
Low pressure sensor
27
High pressure switch
28
Oil sight glass
29
Water filter
30
Frame
31
4-way valve
®
coupling)
32
Liquid receiver
33
Pump (optional)
®
coupling)
34
Buffer tank (optional)
35
Expansion vessel
(optional)
36
Water stop valves
(optional)
37
Buffer tank drain valve
(optional)
38
Regulating valve
(optional)
39
Water safety valve
(optional)
40
Pressure gauge (optional)
41
Eye bolt for lifting the unit
(only for EWYQ080~210)
Packaged air-cooled water chillers
EWYQ080~250DAYN
4PW35559-1D – 03.2011