Back Cover
1. Removal of Connection FPC
2. Removal of Screws
• Remove 5 screws.
• Open the CF cover. Then remove the back cover as letting go the CF card eject button.
!
There are high voltege parts inside. Be careful of this electric shock,
when you remove the cover.
You must discharge the main condenser according to the instruction
of this repair manual before you remove the cover.
#821x2
Disconnect the TFT PCB
connection FPC from the
slider.
WARNING
#827
- D2 ・
CF card eject button
-
VBA10201-R.3577.A
#615x2