Replacement Of Fuses; Replacing The Magnetron - Furuno FR-8062 Operator's Manual

Hide thumbs Also See for FR-8062:
Table of Contents

Advertisement

6.2

Replacement of Fuses

The fuse on the power cable protects the equipment from reverse polarity of the ship's mains and
equipment fault. If the fuse blows, find out the cause before replacing it. Use the correct fuse.
Using the wrong fuse will damage the equipment and void the warranty.
DIsplay unit
Power supply unit
(for FR-8252)
6.3

Replacing the Magnetron

When the magnetron has expired, distant targets cannot be seen on the display. When you feel
that long range performance has decreased, contact a FURUNO agent or dealer about replace-
ment.
Model and magnetron
Model
Magnetron type
FR-8062
MAF1422B
FR-8122
MAF1425B
FR-8252
MAF1458B
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Unit and fuses
Unit
Power supply
12 V
24 V
12 V
24 V
Code No.
000-146-871
000-146-872
000-140-344
6. MAINTENANCE & TROUBLESHOOTING
Fuse
15 A
10 A
15 A
10 A
6-3