Diagnostics
BAKE (Outer)
When the Main Control Board calls for the Outer Bake element, K11 is energized. FIG A shows the K11 relay
activated. FIG B shows a close-up of the P9 connector. L1 (Red) comes into the P9 connection on the relay
board. With the relay closed, L2 is sent to the Outer Bake element. The Outer Bake element draws 6.25 amps.
As with the Inner Bake, the K17 line break relay must also close to provide L2 to the Outer bake element.
K10
K11
BROIL (Inner)
When the Main Control Board calls for the Inner Broil element, K12 is energized. FIG A shows the K12 relay
activated. FIG B shows a close-up of the P6 connector. L1 (Red) comes into the P6 connection on the relay
board. With the relay closed, L2 is sent to the Inner Broil element. The Inner Broil element draws 10.6 amps. As
with the Outer Bake, the K17 line break relay must also close to provide L2 to the Inner Broil element.
K10
K11
K10
K11
© 2008 Viking Preferred Service
K12
K13
K14
K12
K13
K14
K12
K13
K14
From Main Terminal
Block L1
From Main Terminal
To Inner Broil
Block L1
element
To Outer Bake
element
62