15

Operation

15.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
For combination with R410A outdoor unit, refer to the following table:
Outdoor units
RR71~125
Outdoor
temperature
Indoor
temperature
RQ71~125
Outdoor
temperature
Indoor
temperature
RXS35~60
Outdoor
temperature
Indoor
temperature
3MXS40~68
Outdoor
temperature
4MXS68~80
Indoor
5MXS90
temperature
RZQG71~140
Outdoor
temperature
Indoor
temperature
RZQSG71~140
Outdoor
temperature
Indoor
temperature
RZQ200~250
Outdoor
temperature
Indoor
temperature
AZQS71~125
Outdoor
temperature
Indoor
temperature
For combination with R32 outdoor unit, refer to the following table:
Outdoor units
RXM35~60
Outdoor
temperature
Indoor
temperature
3MXM40~68
Outdoor
temperature
4MXM68~80
Indoor
5MXM90
temperature
RZAG71~140
Outdoor
temperature
Indoor
temperature
FCAG35~140AVEB
Split system air conditioners
4P473927-1 – 2017.03
Cooling
Heating
–15~46°C DB
18~37°C DB
12~28°C WB
–5~46°C DB
–9~21°C DB
–10~15°C WB
18~37°C DB
10~27°C DB
12~28°C WB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–15~50°C DB
–19~21°C DB
–20~15.5°C WB
18~37°C DB
10~27°C DB
12~28°C WB
–15~46°C DB
–14~21°C DB
–15~15.5°C WB
20~37°C DB
10~27°C DB
14~28°C WB
–5~46°C DB
–14~21°C DB
–15~15°C WB
20~37°C DB
10~27°C DB
14~28°C WB
–15~46°C DB
–14~21°C DB
–15~15.5°C WB
20~37°C DB
10~27°C DB
14~28°C WB
Cooling
Heating
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–10~46°C DB
–15~24°C DB
–16~18°C WB
18~32°C DB
10~30°C DB
–20~52°C DB
–19.5~21°C DB
–20~15.5°C WB
18~37°C DB
10~27°C DB
12~28°C WB
Outdoor units
RZASG71~140
Outdoor
temperature
Indoor
temperature
AZAS71~140
Outdoor
temperature
Indoor
temperature
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.
15.2

Operating the system

15.2.1

About operating the system

▪ To protect the unit, turn on the main power switch 6 hours before
operation.
▪ If the main power supply is turned off during operation, operation
will restart automatically after the power turns back on again.
15.2.2
About cooling, heating, fan only, and
automatic operation
▪ The air flow rate may adjust itself depending on the room
temperature or the fan may stop immediately. This is not a
malfunction.
15.2.3

About the heating operation

It may take longer to reach the set temperature for general heating
operation than for cooling operation.
The following operation is performed in order to prevent the heating
capacity from dropping or cold air from blowing.
Defrost operation
In heating operation, freezing of the outdoor unit's air cooled coil
increases over time, restricting the energy transfer to the outdoor
unit's coil. Heating capability decreases and the system needs to go
into defrost operation to be able to deliver enough heat to the indoor
units.
The indoor unit will stop fan operation, the refrigerant cycle will
reverse and energy from inside the building will be used to defrost
the outdoor unit coil.
The indoor unit will indicate defrost operation on the display
Hot start
In order to prevent cold air from blowing out of an indoor unit at the
start of heating operation, the indoor fan is automatically stopped.
The display of the user interface shows
time before the fan starts. This is not a malfunction.
15 Operation
Cooling
Heating
–15~46°C DB
–14~21°C DB
–15~15.5°C WB
20~37°C DB
10~27°C DB
14~28°C WB
–15~46°C DB
–14~21°C DB
–15~15.5°C WB
20~37°C DB
10~27°C DB
14~28°C WB
(a)
≤80%
. It may take some
Installer and user reference guide
25
.