Operating Instructions - Apewell SCS-8 Operation Manual

Table of Contents

Advertisement

1. Connect to a source of Grade D or better
breathing air (3000 psi minimum
pressure/6000 PSI maximum pressure) via
the 1/4" FNPT port on the left hand side.
2. Test for leaks and verify pressure on the
left hand (red face) pressure gauge.
3. Adjust the regulator to 3000 PSI (this will show on the blue faced gauge) using the large
black knob, turning clockwise to increase the pressure and counterclockwise to reduce the
pressure.
USE CAUTION WHENEVER WORKING WITH HIGH PRESSURE COMPRESSED AIR
NOTE: Both small black knobs should be
closed at this time.
Capewell Aerial Systems LLC
SCS-8 - Operations Manual
Page 3