DO NOT use P1004 with the blower unit switched off.
DO NOT use P1004 in an atmosphere that is immediately hazardous to user hygiene or health and or
has oxygen content of less than 19.5% or contains unknown substances.
DO NOT use P1004 in an explosive atmosphere.
DO NOT use P1004 in confined spaces or areas of poor ventilation.
DO NOT use P1004 in high winds.
DO NOT alter or modify in any way.
DO NOT touch any of the moving parts.
DO NOT allow water or other liquids to enter the impeller chamber, the filter or battery compartment.
DO NOT use the P1044 as head protection. THIS HEAD COVERING DOES NOT MEET THE
REQUIREMENTS OF AS/NZS 1801. IF HEAD PROTECTION IS REQUIRED CONSULT YOUR
SAFETY OFFICER
4. UNPACKING/ASSEMBLY
Check that correct number of components has been supplied, as in FIGURE 1.
Check that the apparatus is complete, undamaged and correctly assembled. Any damaged or defective
parts must be replaced before use.
-Open P1004 unit and check the spark arrestor, pre-filter and filter, FIGURE 2 (A).
-Replace the filter back into the casing if it's in good condition. FIGURE 2(B).
Place the spark arrestor into the filter cover.
Place the pre-filter into the above combination.
Place the filter into the above combination.
Click the above combination into the Turbo unit.
NOTE: Make sure that the filter is properly placed into the casing while installing.
WARNING: The filter can only be fitted to the turbo unit.
Do NOT directly fit the filter to the helmet/hood.
6
Figure 1
Figure 2 (A)