10: SPECIFICATION

Size
(Blower Assembly)
Weight
Air Filter
Air Flow
Noise Level
Operating Temperature
Storage temperature
Battery Type
Expected Battery Operation Time
Battery Charging Time
Battery Life
LCD Display
Belt Size
11. MARKING EXPLANATION
Powered filtering device:
Australian/New Zealand standard AS/NZS 1716:2012 Respiratory protective devices-
Powered filtering devices incorporating a helmet or hood – Requirements, testing, marking
PAPR-P2 classification of the unit. "P2" defines the level of protection"P"=Particle filter.
18
9-2/5 x 6-1/2 x 2-3/4 in. (240 x 165 x 70 mm)
2.4KG
1*P2
Level 1: >=165L/min
Level 2: 200L/min
Level 3: 230L/min
Max 73dB
23ºC to 131ºC (-5ºC~55ºC)
14ºC to 131ºC (-10ºC~55ºC)
Rechargeable Li-ION 4400mAh
Level 1>8h
Level 2>6h
Level 3>4h
3.5 Hours
500 Charges
Run Time Dependent On Air Flow Rate and Filter Load.
Air flow level and data
Battery capacity
Filter status
35-2/5 x 51-2/5 in. (900mm to 1300mm)