Connecting Remote Receiver; Checking System Operation - MHSC MJ27NR Installation And Operating Istructions

Unvented gas log heater or vented decorative appliance
Table of Contents

Advertisement

ELECTRICAL WIRING (MILLIVOLT)

CONNECTING REMOTE RECEIVER

1. Set remote receiver. See instructions included in receiver kit.
2. Connect the two (2) 1/4"
female connectors to the
TP/TH and TH terminals
on the control valve.
3. Connect the four-pin
connector from the valve
motor to the four-pin con-
nector on the receiver.
4. For further instruction
refer to instruction sheet
included with RCSIT
Remote.
Do not allow wires
to touch grate or
Note: Heat reduces battery life. You can protect the receiver and extend battery life by mounting receiver
The Millivolt system and individual
components may be checked with a
Millivolt meter having a 0-1000 mV
range. Conduct each check shown in
chart below by connection meter test
leads to terminals as indicated.
("A" Reading - Thermostat contacts CLOSED - Control Knob "ON" - Main burner should turn ON)
a. If the reading is more than 175 Millivolts and the automatic valve still does not come on, replace the con-
trol.
b. If the closed circuit reading ("A" reading) is less than 175 Millivolts, determine cause for low reading, pro-
ceed to Section B below.
pilot voltage, 500 Millivolts minimum. If the minimum Millivolt reading is not obtainable, replace pilot.
22
Figure 17 -
Installing Remote Receiver
CHECK
TEST
TO TEST
COMPLETE
A
SYSTEM
THERMOPILE
B
OUTPUT
Valve
Remote Receiver
CONNECT
SWITCH OR
METER LEADS
THERMOSTAT
TO TERMINALS
CONTACTS
2 & 3
CLOSED
1 & 2
OPEN
Connectors
Motor
FP2010
METER
READING
SHOULD BE
MINIMUM 175
MINIMUM 500
86D0024