Configuration File - Huawei S Series White Paper

S series switches istack technology white paper
Hide thumbs Also See for S Series:
Table of Contents

Advertisement

S Series Switches
iStack Technology White Paper
[HUAWEI-GigabitEthernet1/0/5] quit
[HUAWEI] interface gigabitethernet 2/0/5
[HUAWEI-GigabitEthernet2/0/5] eth-trunk 1
[HUAWEI-GigabitEthernet2/0/5] quit
Step 2 Configure the relay function.
# Configure the relay function on proxy device SwitchD.
<HUAWEI> system-view
[HUAWEI] sysname SwitchD
[SwitchD] interface eth-trunk 1
[SwitchD-Eth-Trunk1] mad relay
[SwitchD-Eth-Trunk1] quit
[SwitchD] interface gigabitethernet 0/0/1
[SwitchD-GigabitEthernet0/0/1] eth-trunk 1
[SwitchD-GigabitEthernet0/0/1] quit
[SwitchD] interface gigabitethernet 0/0/2
[SwitchD-GigabitEthernet0/0/2] eth-trunk 1
[SwitchD-GigabitEthernet0/0/2] quit
[SwitchD] interface gigabitethernet 0/0/3
[SwitchD-GigabitEthernet0/0/3] eth-trunk 1
[SwitchC-GigabitEthernet0/0/3] quit
Step 3 Verify the configuration.
# Check detailed MAD configuration of the stack.
<HUAWEI> display mad verbose
Current MAD domain: 0
Current MAD status: Detect
Mad direct detect interfaces configured:
Mad relay detect interfaces configured:
Eth-Trunk1
Excluded ports(configurable):
Excluded ports(cannot be configured):
GigabitEthernet0/0/26
GigabitEthernet0/0/27
GigabitEthernet1/0/26
GigabitEthernet1/0/27
GigabitEthernet2/0/26
GigabitEthernet2/0/27
# Check information about the proxy device SwitchD.
<SwitchD> display mad proxy
Mad relay interfaces configured:
Eth-Trunk1
----End