System Maintenance Reference
GAVD Communication Error
The ID of the GAVD is not identified during initialization.
690
The chip ID of the GAVD cannot be detected by the machine at power-on.
Defective EGB
1.
Replace the EGB.

Controller SC

SC8xx
Service Cycle Power
Incorrect combination of EGB and controller board.
An unexpected error occurs in the EEPROM on the controller board.
819
Controller board defective
1.
Install the correct EGB and controller boards for this machine.
2.
Replace the controller board
USB/ Network Device Error
An interface error in the USB connection or NIB connection occurs.
823
Controller board detective
1.
Replace the controller board.
EEPROM Error
An EEPROM check error at power-on occurs.
824
Controller board detective
1.
Replace the controller board.