Firebrick Wall Installation - Superior VRT4536WS Installation And Operation Instructions Manual

Unvented (vent-free) universal firebox with refractory panels
Table of Contents

Advertisement

REFRACTORY PANEL INSTALLATION
IMPORTANT: Installation of brick
should be done after the fi re-
place is placed in a permanent
location.
1. Remove screen assemblies and all hard-
ware components out of the fi rebox. The
bottom panel is preinstalled in the fi rebox.
Make sure the bottom refractory panels is
centered in the fi rebox and fl ush with the
front of the fi replace.
2. Place cardboard on top of bottom refrac-
tory panel as a protection to prevent ship-
ping and scratching during installation of
the other panels.
LEFT BRICK
PANEL
14
3. Install rear refractory panel. This panel
4. Install the right and left refractory panels
5. Install the upper corner brackets and
UPPER CORNER
BRACKET (2x)
ASH PANEL
Figure 13 - Installing Refractory Panels
SuperiorFireplaces.US.com
has a top and bottom. To determine which
is which, match up the pattern on the rear
panel with the left and right sides before
installing the rear panel. Make sure panel
is center before continuing.
with the gas line knockouts orientated
down toward the bottom refractory. Align
the left and right panels with the rear panel
so the grout lines line up.
tighten set screws (Figure 13).
REAR BRICK
PANEL
RIGHT BRICK
PANEL
BOTTOM
BRICK PANEL
126700-01B