Pioneer PDU-50WX2 Service Manual page 46

Table of Contents

Advertisement

PDU-50WX2
Connector Pin Arrangement
List of use connector, housing and recommended connection cable
Ref No.
CN4007
1
FX2B-100PA-1.27DSL FX2B-100SA-1.27R
Digital signal input
CN4010
2
S14B-XASK-1
Sync. signal input
CN4005
3
S10B-XASK-1
Power supply terminal
Junction connector
4
ELR-03V
AC power input
CN4009
5
B8B-PH-SM3
RS-232C
Use Connector Position
CN4007 (100P)
CN4009 (8P)
46
PCB Connector
Housing
XAP-14V-1
XAP-10V-1
ELP-03V
PHR-8
INTERFACE Assy
Contact
SXA-001T-P0.6
SXA-001T-P0.6
SLF-41T-P1.3E
CN4010 (14P)
S4001
CN4005 (10P)
Junction Connector
Recommended
Lead-wire
AWG#28
AWG#24
AWG#24
AWG#20 (105°C)
S4001
Switch of POWER ON/STANDBY
is possible with S4001 on the
INTERFACE Assy.
At arrow (') direction:
Position in the normal use
At reverse direction:
Forced power on (Note)
Note:
When there are not jig for POWER
ON/STANDBY control or RS-232C
control, can perform power on by
the single module forcibly.
Please set a position at the direction
of arrow (') on the PCB silk in
normal use by all means.