12/2010 MN04802060Z-EN
User Manual
replaces M000902-03, 10/2009
Simatic S7 PG router

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Simatic S7 PG and is the answer not in the manual?

Questions and answers

Summary of Contents for Eaton Simatic S7 PG

  • Page 1 12/2010 MN04802060Z-EN User Manual replaces M000902-03, 10/2009 Simatic S7 PG router...
  • Page 2 All rights reserved, also for the translation. None of this document may be reproduced or processed, duplicated or distributed by electronic sytems in any form (print, photocopy, microfilm or any other process) without the written permission of Eaton Automation AG, St. Gallen. Subject to modifications.
  • Page 3: Proper Use

    No liability is accepted for claims for damages arising from a failure or functional defect in the device. All data specified in this document does not represent warranted properties in the legal sense. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 4: Table Of Contents

    Special Features ....................22     7.1  Restrictions ......................22  7.2  Limitations ......................22  Error Messages ....................23     Command Line Reference ................24     9.1  Parameters ......................24  9.2  Examples ....................... 24  Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 5: General

    Operating system - HMI programming software GALILEO from version 5.2.4 Windows 2000, Windows NT, Windows XP 1.2.2 ARGET SYSTEM Target system Operating system (OS) - MICRO PANEL Windows CE Image Release ≥ 2.12.0 (x) Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 6: Installation On The Programming Pc

    CD drive. If the Setup Wizard does not launch automatically, run the file “S7PGRouter.exe” on the installation CD. Select the desired language from the drop-down menu. Click [OK]. Confirm the subsequent dialog by clicking [Next >]. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 7 Confirm the subsequent dialog by clicking [Next >]. The following dialog will ask you to select an installation directory. The selected directory must contain a Galileo installation. Confirm the dialog by clicking [Next >]. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 8 1 General Select the directory in which the program shortcut will be created. Confirm the dialog by clicking [Next >]. Confirm the subsequent dialog by clicking [Install]. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 9 1 General The next dialog indicates that the installation was successfully completed. Confirm by clicking [Finish]. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 10: Operating Principle

    Refer to your MICRO PANEL user manual for further information on connection, commissioning and operating the MPI and Ethernet interface. Further additional documentation: "System Description Windows CE" Doc. No. MN05010007Z "System Description Networks in Brief" Doc. No. MN05010009Z Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 11: Creating A Network

    The following software should already be installed and users should be familiar with their operation: Siemens Step 7 PLC programming software GALILEO HMI programming software The following documentation provides more useful information on creating networks: "System Description Networks in Brief" Doc. No. MN05010009Z Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 12: Simatic Manager Settings

    Note: All the following screenshots shown and the instructions given apply to Step7 V5.3. First load the S7 project in the SIMATIC Manager. In our example this is a project for an S7-312IFM. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 13: Adding A Router

    Note: The S7 Routing function of the MICRO PANEL is similar to the Routing function of S7 controllers. Refer to the SIMATIC Manager documentation for further information on routing in conjunction with Step7. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 14 Now move to the hardware settings tab of the "Router" and add an S7 CPU with an Ethernet interface. In the Properties dialog, enter the IP address set on the MICRO PANEL ("Router"). Connect the CPU with the Ethernet subnet. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 15: Configuring The Network

    Configure network The network configuration will now show you the "Router" (MICRO PANEL represented by an S7 station) next to the actual S7 station. Add an additional network object of the type "PG/PC". Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 16 4 SIMATIC Manager Settings Now define a free MPI address for the "Router" and select the MPI subnet. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 17 For the PG/PC connection enter the IP address of the PC on which SIMATIC Manager is running, and select under Subnet the already configured Ethernet connection. Under Assigned on the Assignment tab, select "TCP/IP(Auto) ->.." and activate S7ONLINE Access. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 18 The Ethernet connection on the PG/PC highlighted in yellow indicates that the Routing function is active. 192.168.6.10 192.168.6.11 In our example, the S7 station (MPI address 2) can now be programmed via the MICRO PANEL (MPI address 31). Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 19: Micro Panel Settings

    Modify the "Baud rate", "SA" (MPI address of MICRO PANEL) and "HSA" parameters according to the settings you have predefined for the "Router" station in the SIMATIC Manager and confirm with "OK". Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 20 The router connection is now fully configured and you can now access the connected S7 controller. When the PG connection is active, this is indicated by the «S7 PG Router», as shown in the figure. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 21: Galileo Settings

    GALILEO apply. However, the settings of «S7 PG Router» are active if it was started before GRS. Note: Ensure that the settings on the "Router" are the same as those set in GALILEO (see also "Error Messages"). Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 22: Special Features

    The general limitations of the S7 CPU with regard to the number of simultaneous MPI and PG connections apply. «S7 PG Router» has no limitations regarding the number of connections that can be routed simultaneously. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 23: Error Messages

    The "Router" was started before GRS and the station number of the MICRO PANEL does not match the one configured in GALILEO. The GRS will in this case generate an error message on startup. An active communication with the S7 CPU will be established anyway. Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...
  • Page 24: Command Line Reference

    –BR 187500 –sa 31 –hsa 31 …will start «S7 PG Router» with MPI 187.5 kBit as station 31 where the highest station address is also s7route.exe –close …will close an already running «S7 PG Router». Simatic S7 PG router 12/2010 MN04802060Z-EN www.eaton.com...