Disassembly & Reassembly
12-1-14 Separation of ASSY PDP MODULE P-X MAIN BOARD
Part Name
Flat Cable ① Detach all Connectors from the X Main Board.
※ To separate the Flat Cable of the X-Board, press the
upper and the lower sides of the connector.
X-Main
① Remove 4 screws.
Board
: PH,+,WWP,M3,L8,NI PLT
② Remove the X-Main Board.
12-6