Grounding & Power
Grounding
The pro8 is grounded via the 3-pin IEC power connectors on the rear of the unit.
Warning
The unit must be on the same potential as all other system devices/modules.
For Scandinavian countries, ALWAYS use a grounded mains connection, to prevent the
device from being grounded through Ethernet or other signal connections.
Power
The unit is fitted with two independent power supplies:
Input Voltage: 2 x auto sensing 100-240V VAC power supply, 50/60Hz nominal
Power Consumption: < 100W
Connection: 2 x IEC power connectors
Only one supply is required to operate the system. For redundancy, connect both supplies, each to a
separate AC mains circuit. This will ensure continued operation if one of the mains circuits fails.
Warning
Please observe all of the
The device MUST be connected to the mains using the adaptors supplied with the system.
Country-specific mains adaptors will be supplied with the system.
When running with multiple mains supplies, make sure that both circuits lie on the same
ground potential. Otherwise, an internal bridge of two ground wires will lead to a ground
loop!
22
Safety Instructions
BEFORE connecting power to the unit.
V1.0/2
Installation & Configuration
Grounding & Power
V_pro8 Manual