Philips 200WP7EB/00 Service Manual page 23

Table of Contents

Advertisement

Re-programming Analog DDC IC
Step 1: After initialize alignment box, connecting all cables and
box as shown in Fig. 11
PC
To PC
To Monitor
Printer
Port
Step 2: Read DDC data from monitor
1.
Click
icon as shown in Fig. 11 from the tool bar to bring up
the Channels "Configuration Setup" windows as shown in Fig. 12.
2. Select the DDC2Bi as the communication channel.
As shown in Fig. 13.
3. Click OK button to confirm your selection.
4. Click
icon (Read EDID function) to read DDC EDID data from
monitor. The EDID codes will display on screen as shown in Fig. 14.
To Printer port
To Printer port
DDC Instructions
1=Power connector
2=D-SUB connector
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Step 3: Modify DDC data (verify EDID version, week, year)
1.
Click
(new function) icon from the tool bar, bring up
Step 1 of 9 as shown in Fig. 15 .
EDID45 DDC application provides the function selection and
text change (select & fill out) from Step 1 to Step 9.
To Printer port
To Printer port
To Printer port
DC 8~12V
DC 8~12V
DC 8~12V
DC 8~12V
DC 8~12V
To Monitor
To Monitor
To Monitor
D-sub/DVI cable
D-sub/DVI cable
To Monitor
To Monitor
D-sub/DVI cable
D-sub cable
D-sub cable
Power
Power
indicator
indicator
Power
Power
indicator
indicator
Fig. 15
Step 4: Modify DDC data (Monitor Serial No.)
1.
Click
Next
to step7, bring up Fig. 16.
- Serial number can be filled up or be changed at this moment.
- Click Finish to exit the Step window.
Step 5: Write DDC data
1. Configuration should be as Fig. 17. And press OK.
200WP7 LCD
23
Go to cover page
Fig. 16
Fig. 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

200wp7es/00200wp7es/01

Table of Contents