Bryant 538PAQ012RBMA Service Manual page 56

538pr outdoor unit single zone ductless system sizes 09 to 30
Table of Contents

Advertisement

DISASSEMBLY INSTRUCTIONS SIZES 09−12 (CONT)
4
Four-way
valve
5) Remove the
ground wires.
6) Remove the power
supply wires (L1,
L2, S).
7) Remove the
electronic control
box.
How to remove the
four-way valve.
1) Complete the
steps in sections
1,2,3.
2) Recover the
refrigerant from
the refrigerant
circuit.
3) Remove the coil
screw and then
remove the coil.
4) Detach the
welded parts of
four-way valve
and pipe.
5) Remove the
four-way valve
ass'y.
The picture of four-way valve may be different from
the one on your side.
Four-way valve coil, secured by one screw.
56
Four-way
valve
Welded parts

Hide quick links: