Download Print this page
Mitsubishi Electric TC-24A Setting Manual
Mitsubishi Electric TC-24A Setting Manual

Mitsubishi Electric TC-24A Setting Manual

Air-conditioner control system touch controller
Hide thumbs Also See for TC-24A:

Advertisement

Quick Links

Air-conditioner Control System
Touch Controller TC-24A
Initial Setting Manual
This Initial Setting Manual contains information about the settings to be made at the time of installation. Please read the
instructions carefully and make the settings accordingly. Refer to the Installation Manual for how to install the TC-24A Touch
Controller, and refer to the air conditioning unit installation manuals for how to connect the controller cable to the air cond itioning
units, or how to install the air conditioning units. Please remember to give all manuals to the end users after installation is
complete.
1
TC-24A Touch Controller
HOLD button with LED
SETBACK button with LED
Power LED
List of functions available under the "Service menu"
Screen
M-NET address
Remote controller
access
External input mode
Initial Settings
Filter sign
Basic System
Dry mode
Set temperature range
(Schedule)
Time notification
Groups
Initial Settings
Groups
Interlocked operation
Batch deletion
System view
Maintenance
Malfunction log
Software update
Test run
Test run
1
Setting
Sets the M-NET address for the TC-24A.
Selects the type of controllers to prohibit access* from (remote controllers only
or both remote controllers and system controllers).
* Access to ON/OFF, Mode, Set Temp, and Filter Reset.
Selects the external input mode.
Displays or suppresses the Filter sign on the HOME screen.
Includes or excludes Dry mode as an option for the operation mode.
Selects the settable temperature range:
Standard: 67°F(19°C) to 83°F(28°C); Low: 46°F(8°C) to 87°F(30°C);
Manual: Settable to any arbitrary range between 46°F(8°C) and 87°F(30°C).
Sends or does not send the clock synchronization signal once a day to the
controllers and units.
Makes the group settings for the indoor units, LOSSNAY units, DIDO
controllers (PAC-YG66DCA), remote controllers, and sub-system controllers.
Enters the interlock settings between indoor and LOSSNAY units.
Deletes all group and interlock settings collectively.
Displays the information about the indoor units connected to each outdoor unit.
Stores the latest errors. (up to 50)
Updates software.
Runs a test on the connected air conditioning units.
For distribution to dealers and contractors only
Function
Collective ON/OFF
button with LED
Touch panel
Page
4
4
4
4
4
4
5
5
6
6
7
8
8
7

Advertisement

loading

Summary of Contents for Mitsubishi Electric TC-24A

  • Page 1 This Initial Setting Manual contains information about the settings to be made at the time of installation. Please read the instructions carefully and make the settings accordingly. Refer to the Installation Manual for how to install the TC-24A Touch Controller, and refer to the air conditioning unit installation manuals for how to connect the controller cable to the air cond itioning units, or how to install the air conditioning units.
  • Page 2: Service Menu Screen

    TC-24A Screen Confi g urations (1) Screen sequence and Service menu configuration HOME screen GRID (zoom-out) view GRID (zoom-in) view LIST view GROUP view Touch [ ] or [ Touch [ Main Menu screen Touch [ Touch [ Login Page screen *1...
  • Page 3 [Notes on using the TC-24A with the AG-150A controllers*] In addition to making the group and interlock settings on the TC-24A, the same setting information must be entered on the AG-150A controllers. Also, enter the M-NET address for the TC-24A in the System Controller field on the Group Setting screen. Register the M-NET address of the AG-150A on the TC-24A's Group Setting screen.
  • Page 4: External Input Mode

    1) Touch the M-NET Address button (labeled in the figure), and set the TC-24A Controller address on the screen that pops up. The address can be set to 000 or to a value between 201 and 250 (the factory setting is 201).
  • Page 5: Saving The Settings

    (2)-2. Group Settings Enter the group settings on the Groups screen (air conditioning units, general equipment (and their respective group names) that are connected to TC-24A). Touch Initial Settings/Groups button [ ] on the Service Menu screen, and then touch Groups button ] on the Initial Settings/Groups screen to access the Groups screen.
  • Page 6 TC-24A. In batch and on individual group Units can be turned on or off either collectively or by group from the TC-24A. On individual group Only certain groups of units can be turned on or off from the TC-24A.
  • Page 7: Maintenance

    (3) During the test run, verify that air conditioned air is blowing out of the supply air outlet. (4) After checking for normal operation of each unit, stop the units through TC-24A or the local remote controllers. * Refer to the indoor unit installation manual for the detailed information about test run.
  • Page 8 * Consult your dealer if the update is not completed in 10 minutes. 7) After the update has been completed, turn the DIP switch 4 to OFF to restart the TC-24A. When the initialization screen appears, check that the software version that appears at the bottom right corner is correct. If it shows the old version, the update failed.